Evidence map›Paper›PMID 35929433›Full record

ArticleJournal of diabetes science and technology2024

Novel Methods to Understand the Temporal Nature and Accuracy of Delivery for Insulin Infusion Pumps.

S Siddharth Kumar, Deval Karia, Arjun Gopkumar, Pavan G Koty, Manish Arora

Open access · greenAbstract read
In one paragraph

Article in Journal of diabetes science and technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 84% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

S Siddharth KumarUTSAAH Lab, Center for Product Design and Manufacturing, Indian Institute of Science, Bangalore, India.
Deval KariaUTSAAH Lab, Center for Product Design and Manufacturing, Indian Institute of Science, Bangalore, India.
Arjun GopkumarUTSAAH Lab, Center for Product Design and Manufacturing, Indian Institute of Science, Bangalore, India.
Pavan G KotyUTSAAH Lab, Center for Product Design and Manufacturing, Indian Institute of Science, Bangalore, India.
Manish AroraUTSAAH Lab, Center for Product Design and Manufacturing, Indian Institute of Science, Bangalore, India.ORCID 0000-0003-1762-4322
Indian Institute of Science Bangalore · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA wide suite of methods are available to evaluate delivery accuracy of insulin pumps. However, these methods do not capture any temporal information, which may be critical for design of artificial pancreas (AP) systems. We propose a novel video microscopy method to understand the delivery accuracy and temporal nature for a new durable pump under development (IFP), and a commercially available pump (Medtronic 722G, M722G).

methodsThe cannula tip of an infusion set is inserted into a graduated pipette placed under a digital microscope. A video of the delivery is captured to track the fluid meniscus, to measure volumetric delivery rate and accuracy. This was done for a programmed value of 0.5 and 1 U. A similar procedure was adopted to track linear motion of the piston rod, which actuates the reservoir plunger, for a programmed value of 10 U.

resultsIt was observed that the commercially available pump delivers insulin in pulses of 0.05 U every two seconds. The mean absolute volumetric delivery error (MAE) for both pumps was found to be within the values reported previously. More importantly, it was found that a significant fraction of the programmed value is delivered, after completion of the planned bolus duration (IFP: 14.31% vs M722G: 9.38% for 1 U delivery).

conclusionsThe methods presented in this article help understand the delivery dynamics of liquid drug delivery devices. Our results indicate that a significant fraction of insulin delivery happens after the planned bolus duration, which might be important consideration for design of AP systems.

Indexed as

Hypoglycemic AgentsInsulinInsulin Infusion SystemsEquipment DesignHumansTime FactorsVideo RecordingHypoglycemic AgentsInsulinartificial pancreasbolusdelivery accuracydelivery dynamicsinsulin pumpMedtronic 722Gmeniscus trackingvideo microscopy

Identifiers

PMID35929433
PMCPMC11089866
OpenAlexW4289943242

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.