ArticleCureus2022
Transfacet Oblique Lateral Lumbar Interbody Fusion: Technical Description and Early Results.
Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 9 citations in OpenAlex.
- Oblique lumbar interbody fusion with unilateral pedicle screw fixation in a single lateral position for degenerative lumbar diseases.BMC surgery · 2026Article
- Mid-term effects of posterior versus oblique lumbar interbody fusion on spinopelvic alignment and clinical outcomes in lumbar spinal stenosis: a retrospective comparative cohort study.Journal of orthopaedic surgery and research · 2026Article
- Article
- Article
- Transfacet transforaminal lumbar interbody fusion (TF-TLIF) results in greater change in spondylolisthesis and posterior disc height compared to percutaneous TLIF (Perc-TLIF) or minimally invasive TLIF (MIS-TLIF): a retrospective study.Journal of spine surgery (Hong Kong) · 2025Article
- Evolving Paradigms in Spinal Surgery: A Systematic Review of the Learning Curves in Minimally Invasive Spine Techniques.Neurospine · 2024Article
- Using Augmented Reality Technology to Optimize Transfacet Lumbar Interbody Fusion: A Case Report.Journal of clinical medicine · 2024Article
- Effect of Stand-Alone Oblique Lateral Interbody Fusion (OLIF) in Treating Lumbar Spine Lesions.Medical science monitor : international medical journal of experimental and clinical research · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction The oblique lateral lumbar interbody fusion (OLLIF) is a relatively new method of lumbar interbody fusion (LIF) that utilizes a trans-Kambin approach to the disc space. The OLLIF can be performed from T12-S1 in the majority of cases but is occasionally obstructed at the L5-S1 level by osteophytes, an overgrown facet joint and/or prominent sacral ala. Transfacet OLLIF (TF-OLLIF) is a novel method for LIF in which the disc space is accessed by drilling through hypertrophic facets with an OLLIF approach. We provide a proof-of-concept report on the TF-OLLIF surgical technique and report the clinical and perioperative outcomes for the first 29 patients who underwent this procedure. Methods This is a retrospective single surgeon cohort study of 29 patients with lumbar spinal stenosis (LSS) who underwent TF-OLLIF procedures between 8/2018 and 1/2021. The primary outcome was a change in the Oswestry Disability Index (ODI) one year after surgery. Secondary outcomes were surgery time, blood loss, hospital stay, and complications. The TF-OLLIF was performed using the approach and instrumentation of OLLIF. When osseous hypertrophy is reached during the approach, an 8 mm drill is used to drill through the obstructing bone with continuous neuromonitoring. Discectomy and interbody placement are performed with subsequent posterior pedicle screw fixation. Results ODI improved from 49% pre-op to 31% at one-year follow-up. Estimated blood loss ranged from 97.6±93.3 ml for one level TF-OLLIF to 146.2±60.3 ml for a 3+ level TF-OLLIF. Operative time ranged from 57.4±19.5 minutes for a one-level TF-OLLIF to 102.9±27.8 minutes for a 3+ level TF-OLLIF. The average length of hospital stay (LOS) was 0.4±0.8 days for one-level TF-OLLIF and 1.6±1.9 days for 3+ level TF-OLLIF. Complications included five cases of nerve root irritation immediately postoperatively, with three of these patients still reporting mild L5 distribution numbness at the last follow-up, which was not clinically limiting. Conclusion The first 29 cases of TF-OLLIF demonstrated that it is a safe method of interbody fusion that yields good clinical results. This is an important development for practitioners of OLLIF as it enables interbody placement with OLLIF instruments and approach even for challenging L5-S1 levels without compromising surgical outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.