ArticleLasers in medical science2022

Push-out bond strength of two calcium silicate-based cements used for repair of artificial furcal perforation following different power outputs of Nd:YAG laser.

Mohammad Saeed Sheykhrezae, Khosrow Sohrabi, Farshad Khosraviani, Saba Mohammadi, Nasim Chiniforush, Pegah Sarraf

Abstract read
PubMed Publisher
In one paragraph

Article in Lasers in medical science, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mohammad Saeed SheykhrezaeSchool of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID http://orcid.org/0000-0002-1590-5510
Khosrow SohrabiEndodontist, Private Practice, Tehran, Iran.
Farshad KhosravianiD.D.S, University of California Los Angeles, School of Dentistry, Los Angeles, CA, USA.ORCID http://orcid.org/0000-0001-6304-4770
Saba MohammadiSchool of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
Nasim ChiniforushSchool of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID http://orcid.org/0000-0002-3490-170X
Pegah SarrafSchool of Dentistry, Tehran University of Medical Sciences, Tehran, Iran. sarraf_p@sina.tums.ac.ir.ORCID http://orcid.org/0000-0002-2432-7839

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Proper bond strength of endodontic materials is an essential factor in the final success of root canal treatments, including perforation repairs. This study was designed to evaluate the effect of two power outputs of Nd:YAG laser (1064 nm) on push-out bond strength (PBS) of ProRoot mineral trioxide aggregate (MTA) and calcium-enriched mixture cement (CEM Cement) in the repair of artificial furcal perforations. This ex vivo study enrolled 66 extracted human molars. After preparing the access cavity, perforations were created on the floor of the pulp chamber with a diameter of 1.4 mm. The teeth were randomly distributed into the following six groups according to the repair material (MTA and CEM) and power output of laser irradiation (1 W and 1.5 W); A: MTA (case), B: CEM (case), C: Nd:YAG (1 W)/MTA, D: Nd:YAG (1 W)/CEM, E: Nd:YAG (1.5 W)/MTA, and F: Nd:YAG (1.5 W)/CEM. Then, a universal testing machine was utilized to assess the PBS. Data analysis was performed using ANOVA and T tests. Significant level was considered at P < 0.05. The highest mean ± SD of PBS was noted in Group Nd:YAG (1 W)/MTA (58.92 ± 36.13), followed by Nd:YAG (1.5 W)/MTA > Nd:YAG (1.5 W)/CEM > Nd:YAG (1 W)/CEM > MTA > and CEM. A significant difference was noted between laser and non-laser applications (P < 0.05). However, the increase of power output from 1 to 1.5 W had no significant influence on PBS (P > 0.05). The PBS of MTA groups was always significantly greater than that of CEM groups (P < 0.05). Although Nd:YAG laser irradiation positively influenced on PBS values in both material studied, increasing power output was not effective.

Indexed as

Lasers, Solid-StateRoot Canal Filling MaterialsCalcium CompoundsHumansMolarSilicatesCalcium Compoundscalcium silicateRoot Canal Filling MaterialsSilicatesCalcium-enriched mixture cementMineral trioxide aggregateNd:YAG laserNeodymium-doped yttrium aluminum garnet laserPush-out bond strength

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.