Evidence map›Paper›PMID 35921020›Full record

ArticleMagma (New York, N.Y.)2023

Pilot tone-based prospective correction of respiratory motion for free-breathing myocardial T1 mapping.

Juliane Ludwig, Kirsten Miriam Kerkering, Peter Speier, Tobias Schaeffter, Christoph Kolbitsch

Abstract read
In one paragraph

Article in Magma (New York, N.Y.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Juliane LudwigPhysikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Abbestr. 2-12, 10587, Berlin, Germany. juliane.ludwig@ptb.de.ORCID http://orcid.org/0000-0003-4042-8071
Kirsten Miriam KerkeringPhysikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Abbestr. 2-12, 10587, Berlin, Germany.ORCID http://orcid.org/0000-0002-8165-5943
Peter SpeierSiemens Healthcare, Erlangen, Germany.ORCID http://orcid.org/0000-0003-0449-1145
Tobias SchaeffterDepartment of Biomedical Engineering, Technische Universität Berlin, Berlin, Germany.ORCID http://orcid.org/0000-0003-1310-2631
Christoph KolbitschPhysikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Abbestr. 2-12, 10587, Berlin, Germany.ORCID http://orcid.org/0000-0002-4355-8368

Funding

Deutsche Forschungsgemeinschaft CRC1340 Matrix in VisionDeutsche Forschungsgemeinschaft DFG KO 5369/1-1Deutsche Forschungsgemeinschaft GRK2260-BIOQICEuropean Metrology Programme for Innovation and Research 18HLT05 QUIERO
6 · The paper itself

Abstract

objectiveTo provide respiratory motion correction for free-breathing myocardial T1 mapping using a pilot tone (PT) and a continuous golden-angle radial acquisition. MATERIALS AND

methodsDuring a 45 s prescan the PT is acquired together with a dynamic sagittal image covering multiple respiratory cycles. From these images, the respiratory heart motion in head-feet and anterior-posterior direction is estimated and two linear models are derived between the PT and heart motion. In the following scan through-plane motion is corrected prospectively with slice tracking based on the PT. In-plane motion is corrected for retrospectively. Our method was evaluated on a motion phantom and 11 healthy subjects.

resultsNon-motion corrected measurements using a moving phantom showed T1 errors of 14 ± 4% (p < 0.05) compared to a reference measurement. The proposed motion correction approach reduced this error to 3 ± 4% (p < 0.05). In vivo the respiratory motion led to an overestimation of T1 values by 26 ± 31% compared to breathhold T1 maps, which was successfully corrected to an average difference of 3 ± 2% (p < 0.05) between our free-breathing approach and breathhold data. DISCUSSION: Our proposed PT-based motion correction approach allows for T1 mapping during free-breathing with the same accuracy as a corresponding breathhold T1 mapping scan.

Indexed as

Magnetic Resonance ImagingMyocardiumHumansProspective StudiesRespirationRetrospective StudiesCardiovascular MRPilot toneProspective respiratory motion correctionT1 mapping

Identifiers

PMID35921020
PMCPMC9992053

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.