Evidence map›Paper›PMID 35918676›Full record

ArticleBMC endocrine disorders2022

Body fat assessment in youth with overweight or obesity by an automated bioelectrical impedance analysis device, in comparison with the dual-energy x-ray absorptiometry: a cross sectional study.

Hanen Samouda, Jérémie Langlet

Open access · goldAbstract read
In one paragraph

Article in BMC endocrine disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
2.6field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it, 26 citations in OpenAlex.

  1. Guideline
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Hanen SamoudaPrecision Health Department, Luxembourg Institute of Health, Strassen, Luxembourg. hanene.samouda@lih.lu.ORCID https://orcid.org/0000-0003-3450-4189
Jérémie LangletBusiness Development Office, Luxembourg Institute of Health, Strassen, Luxembourg.
Luxembourg Institute of Health · LU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBioelectrical impedance analysis (BIA) is a widely used method to assess total body fat (TBF) depots characterising obesity. Automated BIA devices provide an inexpensive and easy assessment of TBF, making them widely available to the general public and healthcare providers without specific qualification to assess body composition. The equations included in the automated BIA devices have been developed in very few specific populations, which means that they are not suitable to assess TBF for everyone and need to be validated before use in other populations. The aim of the present work is to evaluate the accuracy of the automated BIA device Tanita® BC-532 in youth of White European ethnicity, compared with the dual-energy x-ray absorptiometry (DEXA), gold standard measurement of TBF.

methodsTotal body fat percentage (TBF%) was measured with the BIA device Tanita® BC-532 and DEXA (Hologic® QDR4500W) in 197 youth of White European ethnicity (N = 104 girls), 7-17 years old, and visiting the Diabetes & Endocrinology Care Paediatrics Clinic, Centre Hospitalier de Luxembourg, for overweight or obesity management.

resultsTBF% evaluated with BIA was significantly correlated with TBF% measured with DEXA in both boys (r

conclusionsThe automated BIA device Tanita® BC-532 appears to be not accurate to assess total body fat in youth with overweight or obesity. There is a need to calibrate the BIA device before its use in the populations where it was not previously validated.

Indexed as

ObesityOverweightAbsorptiometry, PhotonAdipose TissueAdolescentBody CompositionBody Mass IndexChildCross-Sectional StudiesElectric ImpedanceFemaleHumansMaleAdiposity, Body mass index, Overweight, Obesity, Fat mass, Dual-energy x-ray absorptiometry, Bioimpedance

Identifiers

PMID35918676
PMCPMC9347159
OpenAlexW4289519038

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.