ArticlePloS one2022
Accuracy of CT perfusion ischemic core volume and location estimation: A comparison between four ischemic core estimation approaches using syngo.via.
Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Understanding CT Perfusion in Acute Ischemic Stroke: How Algorithms Shape Perfusion Maps.Diagnostics (Basel, Switzerland) · 2026Review
- Comparison of CT-perfusion software packages and validation with true infarct core in patients with acute ischemic stroke.BMC medical imaging · 2025Article
- Estimation of Acute Infarct Core and Hypoperfused Region from Baseline Noncontrast Computed Tomography and Computed Tomography Angiography Scans of Patients with Ischemic Stroke.Stroke (Hoboken, N.J.) · 2025Article
- Computed tomography perfusion-defined ischemic core predicts functional outcome after basilar artery thrombectomy.Frontiers in neurology · 2025Article
- Assessing the accuracy of automated CT perfusion software in excluding acute stroke: a comparative study of two software packages.Frontiers in neuroimaging · 2025Article
- Accuracy of computed tomography perfusion-defined ischemic core and follow-up infarction after basilar artery thrombectomy.Frontiers in neurology · 2025Article
- Accuracy of Four Different CT Perfusion Thresholds for Ischemic Core Volume and Location Estimation Using IntelliSpace Portal.Journal of cardiovascular development and disease · 2023Article
- Spatial accuracy of computed tomography perfusion to estimate the follow-up infarct on diffusion-weighted imaging after successful mechanical thrombectomy.BMC neurology · 2023Article
- Role of artificial intelligence and machine learning in the diagnosis of cerebrovascular disease.Frontiers in human neuroscience · 2023Review
- Agreement between estimated computed tomography perfusion ischemic core and follow-up infarct on diffusion-weighted imaging.Insights into imaging · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND AND
objectiveComputed tomography perfusion (CTP) is widely used in the evaluation of acute ischemic stroke patients for endovascular thrombectomy (EVT). The stability of CTP core estimation is suboptimal and varies between software packages. We aimed to quantify the volumetric and spatial agreement between the CTP ischemic core and follow-up infarct for four ischemic core estimation approaches using syngo.via.
methodsWe included successfully reperfused, EVT-treated patients with baseline CTP and 24h follow-up diffusion weighted magnetic resonance imaging (DWI) (November 2017-September 2020). Data were processed with syngo.via VB40 using four core estimation approaches based on: cerebral blood volume (CBV)<1.2mL/100mL with and without smoothing filter, relative cerebral blood flow (rCBF)<30%, and rCBF<20%. The follow-up infarct was segmented on DWI.
resultsIn 59 patients, median estimated CTP core volumes for four core estimation approaches ranged from 12-39 mL. Median 24h follow-up DWI infarct volume was 11 mL. The intraclass correlation coefficient (ICC) showed moderate-good volumetric agreement for all approaches (range 0.61-0.76). Median Dice was low for all approaches (range 0.16-0.21). CTP core overestimation >10mL occurred least frequent (14/59 [24%] patients) using the CBV-based core estimation approach with smoothing filter.
conclusionsIn successfully reperfused patients who underwent EVT, syngo.via CTP ischemic core estimation showed moderate volumetric and spatial agreement with the follow-up infarct on DWI. In patients with complete reperfusion after EVT, the volumetric agreement was excellent. A CTP core estimation approach based on CBV<1.2 mL/100mL with smoothing filter least often overestimated the follow-up infarct volume and is therefore preferred for clinical decision making using syngo.via.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.