ArticleTranslational vision science & technology2022
Long- and Short-Term Variability of Perimetry in Glaucoma.
Article in Translational vision science & technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 13 citations in OpenAlex.
- Eye-tracking biomarkers for glaucoma based on saccadic reaction time: a controlled clinical study.Frontiers in ophthalmology · 2025Trial
- Comparison of AIZE-EX and SITA-standard visual field measurements in patients with glaucoma.Japanese journal of ophthalmology · 2026Article
- Predicting Variability and Reliability in Visual Field Testing: Short- and Long-Term Approaches.Ophthalmology science · 2026Article
- Evaluation of the visual field test algorithm: the Ambient Interactive ZEST-EX (AIZE-EX).Scientific reports · 2026Article
- ET-1, MMPs, ZAG, and APN Link Reduced Ocular Perfusion to Glaucoma.Biomolecules · 2025Article
- High-density perimetry in the assessment of foveal avascular zone and macular structure in glaucoma.PloS one · 2025Article
- Improving the Accuracy and Speed of Visual Field Testing in Glaucoma With Structural Information and Deep Learning.Translational vision science & technology · 2023Article
- Detectability of Visual Field Defects in Glaucoma Using Moving Versus Static Stimuli for Perimetry.Translational vision science & technology · 2023Article
- A Data-Driven Model for Simulating Longitudinal Visual Field Tests in Glaucoma.Translational vision science & technology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
Abstract
Purpose: Test-retest variability in perimetry consists of short-term and long-term components, both of which impede assessment of progression. By minimizing and quantifying the algorithm-dependent short-term variability, we can quantify the algorithm-independent long-term variability that reflects true fluctuations in sensitivity between visits. We do this at locations with sensitivity both < 28 dB (when the stimulus is smaller than Ricco's area and complete spatial summation can be assumed) and > 28 dB (when partial summation occurs). Methods: Frequency-of-seeing curves were measured at four locations of 35 participants with glaucoma. The standard deviation of cumulative Gaussian fits to those curves was modeled for a given sensitivity and used to simulate the expected short-term variability of a 30-presentation algorithm. A separate group of 137 participants was tested twice with that algorithm, 6 months apart. Long-term variance at different sensitivities was calculated as the LOESS fit of observed test-retest variance minus the LOESS fit of simulated short-term variance. Results: Below 28 dB, short-term variability increased approximately linearly with increasing loss. Long-term variability also increased with damage below this point, attaining a maximum standard deviation of 2.4 dB at sensitivity 21 dB, before decreasing due to the floor effect of the algorithm. Above 30 dB, the observed test-retest variance was slightly smaller than the simulated short-term variance. Conclusions: Long-term and short-term variability both increase with damage for perimetric stimuli smaller than Ricco's area. Above 28 dB, long-term variability constitutes a negligible proportion of test-retest variability. Translational Relevance: Fluctuations in true sensitivity increase in glaucoma, even after accounting for increased short-term variability. This long-term variability cannot be reduced by altering testing algorithms alone.
Indexed as
Identifiers
What OpenQuestion holds