Evidence map›Paper›PMID 35916311›Full record

ArticleMagnetic resonance in medicine2022

Reduced-field of view three-dimensional MR acoustic radiation force imaging with a low-rank reconstruction for targeting transcranial focused ultrasound.

Huiwen Luo, Michelle K Sigona, Thomas J Manuel, Marshal A Phipps, Li M Chen, Charles F Caskey, William A Grissom

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Magnetic Resonance Acoustic Radiation Force Imaging (MR-ARFI).Journal of magnetic resonance imaging : JMRI · 2025
    Review
  3. Design and Validation of a Patient-Specific Stereotactic Frame for Transcranial Ultrasound Therapy.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Huiwen LuoBiomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA.ORCID 0000-0003-3626-6233
Michelle K SigonaBiomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA.
Thomas J ManuelBiomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA.
Marshal A PhippsVanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA.
Li M ChenVanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA.
Charles F CaskeyVanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA.
William A GrissomBiomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA.ORCID 0000-0002-3289-1827

Funding

Postdoctoral Training in Biomedical MRI and MRST32EB001628 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI John C Gore · 2003 to 2026
$7.0M
Development of an MRgFUS system for precision-targeted neuromodulation of pain circuits with simultaneous functional MRIU18EB029351 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI CASKEY, CHARLES F, CHEN, LI MIN · 2019 to 2019
$3.6M
Replacement and Upgrade of a 3T MR Scanner for ResearchS10OD021771 · OD · VANDERBILT UNIVERSITY MEDICAL CENTER · PI GORE, JOHN C · 2016 to 2016
$2.0M
NIBIB NIH HHS T32 EB001628NIBIB NIH HHS U18 EB029351NIH HHS S10 OD021771
6 · The paper itself

Abstract

purposeTo rapidly image and localize the focus in MR-guided focused ultrasound (FUS) while maintaining a low ultrasound duty cycle to minimize tissue effects.

methodsMR-acoustic radiation force imaging (ARFI) is key to targeting FUS procedures such as neuromodulation, and works by encoding ultrasound-induced displacements into the phase of MR images. However, it can require long scan times to cover a volume of tissue, especially when minimizing the FUS dose during targeting is paramount. To simultaneously minimize scan time and the FUS duty cycle, a 2-min three-dimensional (3D) reduced-FOV spin echo ARFI scan with two-dimensional undersampling was implemented at 3T with a FUS duty cycle of 0.85%. The 3D k-space sampling scheme incorporated uniform undersampling in one phase-encoded axis and partial Fourier (PF) sampling in the other. The scan interleaved FUS-on and FUS-off data collection to improve displacement map quality via a joint low-rank image reconstruction. Experiments in agarose and graphite phantoms and living macaque brains for neuromodulation and blood-brain barrier opening studied the effects of the sampling and reconstruction strategy on the acquisition, and evaluated its repeatability and accuracy.

resultsIn the phantom, the distances between displacement centroids of 10 prospective reconstructions and a fully sampled reference were below 1 mm. In in vivo brain, the distances between centroids ranged from 1.3 to 2.1 mm. Results in phantom and in vivo brain both showed that the proposed method can recover the FUS focus compared to slower fully sampled scans.

conclusionThe proposed 3D MR-ARFI reduced-FOV method enables rapid imaging of the FUS focus while maintaining a low FUS duty cycle.

Indexed as

GraphiteAcousticsImaging, Three-DimensionalMagnetic Resonance ImagingPhantoms, ImagingProspective StudiesSepharoseGraphiteSepharose3Dfocused-ultrasoundlow-rankMR-ARFIMRIreduced-FOV

Identifiers

PMID35916311
PMCPMC9529839

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.