Evidence map›Paper›PMID 35913954›Full record

ArticlePloS one2022

Accuracy of a patient-specific 3D-printed drill guide for placement of bicortical screws in atlantoaxial ventral stabilization in dogs.

Yong Yu, Jinsu Kang, Namsoo Kim, Suyoung Heo

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.3field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Yong YuDepartment of Veterinary Surgery, Jeonbuk National University, Gobong-ro, Iksan, South Korea.
Jinsu KangDepartment of Veterinary Surgery, Jeonbuk National University, Gobong-ro, Iksan, South Korea.
Namsoo KimDepartment of Veterinary Surgery, Jeonbuk National University, Gobong-ro, Iksan, South Korea.
Suyoung HeoDepartment of Veterinary Surgery, Jeonbuk National University, Gobong-ro, Iksan, South Korea.ORCID 0000-0002-7733-3263
Jeonbuk National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Atlantoaxial instability (AAI) in dogs refers to abnormal motion at the C1-C2 articulation due to congenital or developmental anomalies. Surgical treatment options for AAI include dorsal and ventral stabilization techniques. Ventral stabilization techniques commonly utilize transarticular and vertebral body screws or pins. However, accurate screw insertion into the vertebrae of C1 and C2 is difficult because of the narrow safety corridors. This study included 10 mixed dogs, 1 Pomeranian, and 1 Shih-Tzu cadaver. All dogs weighed <10 kg. Each specimen was scanned using computed tomography (CT) from the head to the 7th cervical vertebrae. This study used 12 bone models and 6 patient-specific drill guides. Bone models were made using CT images and drill guides were created through a CAD (computer-aided design) program. A total of six cortical screws were used for each specimen. Two screws were placed at each of the C1, C2 cranial, and C2 caudal positions. Postoperative CT images of the cervical region were obtained. The degree of cortex breaching and angle and bicortical status of each screw was evaluated. The number of screws that did not penetrate the vertebral canal was higher in the guided group (33/36, 92%) than in the control group (20/36, 56%) (P = 0.003). The screw angles were more similar to the reference angle compared to the control group. The number of bicortically applied screws in the control group was 28/36 (78%) compared to 34/36 (94%) in the guided group. Differences between the preoperative plan and the length of the applied screw at the C1 and C2 caudal positions were determined by comparing the screw lengths in the guide group. The study results demonstrated that the use of a patient-specific 3D-printed drill guide for AAI ventral stabilization can improve the accuracy of the surgery. The use of rehearsal using bone models and a drilling guide may improve screw insertion accuracy.

Indexed as

Joint InstabilityPedicle ScrewsSpinal FusionAnimalsBone ScrewsCervical VertebraeDogsInternal FixatorsPrinting, Three-Dimensional

Identifiers

PMID35913954
PMCPMC9342780
OpenAlexW4289337222

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.