Evidence map›Paper›PMID 35913540›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2023

Risk factors for hardware-related complications after extra-articular distal humerus fracture fixation using an anatomical locking plate.

Hyoung-Seok Jung, Yoo-Sun Won, Yang-Seon Choi, Jae-Sung Lee

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Hyoung-Seok JungDepartment of Orthopaedic Surgery, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea.ORCID http://orcid.org/0000-0003-4756-6258
Yoo-Sun WonDepartment of Orthopaedic Surgery, Hospital of Chung-Ang University of Medicine, 224-1 Heukseok-dong, Dongjak-gu, Seoul, 156-755, Korea.
Yang-Seon ChoiDepartment of Orthopaedic Surgery, Hospital of Chung-Ang University of Medicine, 224-1 Heukseok-dong, Dongjak-gu, Seoul, 156-755, Korea.
Jae-Sung LeeDepartment of Orthopaedic Surgery, Hospital of Chung-Ang University of Medicine, 224-1 Heukseok-dong, Dongjak-gu, Seoul, 156-755, Korea. boneman@cau.ac.kr.ORCID http://orcid.org/0000-0002-3745-9048
Chung-Ang University · KRChung-Ang University Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe aimed to identify the incidence and risk factors of hardware-related complications in patients treated with anatomical locking plate fixation for extra-articular distal humerus fractures.

methodsFrom 2013 to 2020, patients with extra-articular distal humerus fractures who underwent open reduction and internal fixation with an extra-articular distal humerus locking plate (EADHP) were retrospectively reviewed and categorized according to the presence/absence of hardware-related complications. Hardware-related complications were defined as the occurrence of skin prominence on the plate and discomfort in activities of daily living. Patient demographics, the lateral condylar angle, lateral body length, shaft-condylar angle of the humerus, and plate length were analyzed.

resultsOf the 29 patients, 10 (34%) did not develop hardware-related complications (group A), whereas 19 (66%) did (group B). Patient demographics did not differ between the groups. However, the number of patients who underwent hardware removal was significantly greater in group B (16/19) than in group A (4/10; p = 0.032). Radiologic assessment revealed no significant difference in the lateral condylar or shaft-condylar angle. However, the lateral body length was greater in group A than in group B (44.5 ± 4.8 vs. 39.5 ± 3.7, p = 0.007). The plate length significantly differed between the groups. Twelve of 19 (63%) patients in group B received short-hole plates (six holes), while nine of ten (90%) patients in group A received long-hole plates (eight holes). In the multivariable analysis, the lateral body length of the distal humerus (p = 0.047, odds ratio = 0.734, 95% confidence interval: 0.542-0.996) and plate length (p = 0.036, odds ratio = 0.076, 95% confidence interval: 0.542-0.996) were associated with hardware-related complications.

conclusionsMost patients developed hardware-related complications, particularly with short plates, mainly because of the narrow lateral body length of the distal humerus. Surgeons should be careful to secure EADHP in the appropriate position, especially when short plates are used in patients with narrow lateral body length.

Indexed as

Humeral FracturesHumeral Fractures, DistalActivities of Daily LivingBone PlatesFracture Fixation, InternalHumansHumerusRetrospective StudiesRisk FactorsTreatment OutcomeComplicationFractureHumerusLocking plate

Identifiers

PMID35913540
OpenAlexW4289201536

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.