Evidence map›Paper›PMID 35912943›Full record

ArticleANZ journal of surgery2022

Prophylactic onlay mesh at emergency laparotomy: promising early outcomes with long-acting synthetic resorbable mesh.

Daniah Alsaadi, Ian Stephens, Lydia O Simmons, Magda Bucholc, Michael Sugrue

Open access · hybridAbstract read
In one paragraph

Article in ANZ journal of surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Review
  5. Variable use of modern abdominal wall closure techniques at emergency laparotomy - an international, cross-sectional survey of surgical practice.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025
    Article
  6. Observational
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 3 countries.

Daniah AlsaadiDepartment of Surgery, Letterkenny University Hospital, Letterkenny, Ireland.ORCID 0000-0003-3497-1828
Ian StephensDepartment of Surgery, Letterkenny University Hospital, Letterkenny, Ireland.
Lydia O SimmonsDepartment of Surgery, Letterkenny University Hospital, Letterkenny, Ireland.
Magda BucholcIntelligent Systems Research Centre, School of Computing, Engineering and Intelligent Systems, Ulster University, Derry, UK.
Michael SugrueDepartment of Surgery, Letterkenny University Hospital, Letterkenny, Ireland.
Letterkenny University Hospital · IEUniversity of Ulster · GB

Funding

Donegal Clinical and Research AcademyEuropean Union's INTERREG VA Programme
6 · The paper itself

Abstract

backgroundCareful surgical strategy is paramount in balancing the prevention of fascial dehiscence, incisional hernia (IH) and fear of additional mesh-related wound complications post-laparotomy. This study aims to review early outcomes of patients undergoing an emergency laparotomy with prophylactic TIGR® mesh, used to reduce early fascial dehiscence and potential subsequent IH.

methodA retrospective, ethically approved review of 24 consecutive patients undergoing prophylactic TIGR® mesh placement during emergency laparotomies by a single surgeon between January 2017 and June 2021 at a University Hospital. A standardized approach included onlay positioning of the mesh, small-bite fascial closure, and a wound bundle. We recorded patient demographics, operative indications, findings, degree of peritonitis, postoperative complications, and mortality.

resultThe study included 24 patients; 16/24 (66.6%) were female and median age was 72.5 (range 31-86); 14/24 patients were ASA grade III or greater; 4/24 patients (16.6%) developed six complications and 3/6 occurred in a single patient. Complications included subphrenic abscess, seroma, intrabdominal hematoma, enterocutaneous fistula leading to deep wound infection and small bowel perforation. Five (20.8%) patients died in hospital; central venous catheter sepsis (n = 1), fungal septicaemia (n = 1) and multiorgan failure (n = 3). Surgical site infection and seroma rates were low, occurring in 2/24 patients (4% each).

conclusionThis study has identified that prophylactic onlay mesh in patients undergoing an emergency laparotomy is not associated with significant wound infection or seroma when used with an active wound bundle. The wider use of TIGR® to prevent fascial dehiscence and potential long-term IH prevention should be considered.

Indexed as

Abdominal Wound Closure TechniquesIncisional HerniaAgedFemaleHumansLaparotomyMaleRetrospective StudiesSeromaSurgical MeshSurgical Wound Infectionburst abdomenemergency laparotomyincisional herniapatient outcomesprophylactic mesh placementseromasurgical site infectionTIGR

Identifiers

PMID35912943
PMCPMC9540974
OpenAlexW4289335677

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.