Evidence map›Paper›PMID 35907886›Full record

ArticleJournal of orthopaedic surgery and research2022

Automated measurement of alpha angle on 3D-magnetic resonance imaging in femoroacetabular impingement hips: a pilot study.

Nastassja Pamela Ewertowski, Christoph Schleich, Daniel Benjamin Abrar, Harish S Hosalkar, Bernd Bittersohl

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Nastassja Pamela EwertowskiDepartment for Orthopedics and Trauma Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.
Christoph SchleichMVZ Radiology Network NRW, Düsseldorf, Germany.
Daniel Benjamin AbrarDepartment of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.
Harish S HosalkarParadise Valley Hospital, San Diego, CA, USA.
Bernd BittersohlDepartment for Orthopedics and Trauma Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany. bernd.bittersohl@med.uni-duesseldorf.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFemoroacetabular impingement (FAI) syndrome is an established pre-osteoarthritic condition. Diagnosis is based on both clinical and radiographic parameters. An abnormal manually calculated alpha angle in magnetic resonance imaging (MRI) is traditionally utilized to diagnose abnormal femoral head-neck offset. This pilot study aimed to assess the feasibility of automated alpha angle measurements in patients with FAI syndrome, and to compare automated with manual measurements data with regard to the time and effort needed in each method.

methodsAlpha angles were measured with manual and automated techniques, using postprocessing software in nineteen hip MRIs of FAI syndrome patients. Two observers conducted manual measurements. Intra- and inter-observer reproducibility and correlation of manual and automated alpha angle measurements were calculated using intra-class correlation (ICC) analysis. Both techniques were compared regarding the time taken (in minutes) and effort required, measured as the amount of mouse button presses performed.

resultsThe first observer's intra-observer reproducibility was good (ICC 0.77; p < 0.001) while the second observer's was good-to-excellent (ICC 0.93; p < 0.001). Inter-observer reproducibility between both observers in the first (ICC 0.45; p < 0.001) and second (ICC 0.56; p < 0.001) manual alpha angle assessment was moderate. The intra-class correlation coefficients between manual and automated alpha angle measurements were ICC = 0.24 (p = 0.052; observer 1, 1st measurement), ICC = 0.32 (p = 0.015; observer 1, 2nd measurement), ICC = 0.50 (p < 0.001; observer 2, 1st measurement), and ICC = 0.45 (p < 0.001; observer 2, 2nd measurement). Average runtime for automatic processing of the image data for the automated assessment was 16.6 ± 1.9 min. Automatic alpha angle measurements took longer (time difference: 14.6 ± 3.9 min; p < 0.001) but required less effort (difference in button presses: 231 ± 23; p < 0.001). While the automatic processing is running, the user can perform other tasks.

conclusionsThis pilot study demonstrates that objective and reliable automated alpha angle measurement of MRIs in FAI syndrome hips is feasible. Trial registration The Ethics Committee of the University of Düsseldorf approved our study (Registry-ID: 2017084398).

Indexed as

Femoracetabular ImpingementAnimalsHipHip JointMagnetic Resonance ImagingMicePilot ProjectsReproducibility of ResultsAlpha angleAutomatic diagnostic toolAutomatic measurementFAI syndromeHipMRI

Identifiers

PMID35907886
PMCPMC9338591

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.