ArticleArchives of orthopaedic and trauma surgery2023
Lateral locking plate plus antero-posterior lag screws techniques for the management of posterolateral tibial plateau fracture: preliminary clinical results and biomechanical study.
Article in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it.
- A systematic analysis assessing epidemiological characteristics and surgical outcomes of posterolateral tibial plateau fractures.European journal of medical research · 2025Pooled it
- Comparison of Gerdy's tubercle osteotomy versus conventional anterolateral approach for posterolateral tibial plateau fractures: a retrospective cohort study.BMC musculoskeletal disorders · 2026Article
- Biomechanical performance of proximal tibia fracture plates: A review.Chinese journal of traumatology = Zhonghua chuang shang za zhi · 2026Review
- Application of a combined cancellous lag screw enhances the stability of locking plate fixation of osteoporotic lateral tibial plateau fracture by providing interfragmentary compression force.Journal of orthopaedic surgery and research · 2024Article
- Finite element analysis of a novel anatomical plate in posterolateral plateau fractures.Frontiers in surgery · 2024Article
- Potential problem and solution of lateral plate postposition for the posterolateral tibial plateau fracture.Journal of orthopaedic surgery and research · 2023Article
- High return to sports rates after operative treatment of patella fractures.European journal of medical research · 2023Article
- The study of biomechanics and finite element analysis on a novel plate for tibial plateau fractures via anterolateral supra-fibular-head approach.Scientific reports · 2023Article
- Biomechanics and finite element analysis comparing posterior T-plates with LCP for fixation of posterolateral tibial plate fractures.Frontiers in bioengineering and biotechnology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
introductionTo date, there is no consensus on the optimal surgical strategy for the treatment of posterolateral tibial plateau fracture (PLF). This study introduced a novel, simple technique for treating PLF with a lateral locking plate plus antero-posterior lag screws (LPpLS).
methodsWe conducted a retrospective case series of 42 patients (Female/Male 19/23) with PLF treated with LPpLS between 1 July 2016 and 30 June 2019. Several pre- and postoperative outcomes were recorded, including operative time, intraoperative blood loss, CT findings, HSS, and ROM. For biomechanical studies, seventy synthetic tibiae with a simulated posterolateral split fracture were divided into seven groups. The biomechanical evaluation included displacement measurement at axial compression and fatigue testing.
resultsForty-two eligible patients were followed up for an average of 18 months (range 14-21 months). Postoperative radiographs and CT showed good positioning of plates and screws, no fracture fragment loss, and normal articular surfaces in all 42 cases. The biomechanical study showed that the axial stiffness of LPpLS was in the same fashion as the posterior buttress plate and better than the other fixation methods (P < 0.05). Additionally, the LPpLS group had a smaller displacement of fracture fragments along the X-axis (medial to lateral direction) than the BP group (P < 0.01).
conclusionsThe LPpLS technique could implement good reconstruction of the PLF, showing satisfactory therapeutic effect. The biomechanical evaluation demonstrated that the LPpLS had better stability in three-dimensional directions for PLF than other fixation strategies.
Indexed as
Identifiers
35907003What OpenQuestion holds
Registered trials