ArticleJournal of applied clinical medical physics2022

Improving reproducibility and performance of radiomics in low-dose CT using cycle GANs.

Junhua Chen, Leonard Wee, Andre Dekker, Inigo Bermejo

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. A Physics-Informed Deep Neural Network for Harmonization of CT Images.IEEE transactions on bio-medical engineering · 2024
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Junhua ChenDepartment of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre+, Maastricht, ET, Netherlands.
Leonard WeeDepartment of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre+, Maastricht, ET, Netherlands.
Andre DekkerDepartment of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre+, Maastricht, ET, Netherlands.
Inigo BermejoDepartment of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre+, Maastricht, ET, Netherlands.

Funding

BIONIC NWO 629.002.205CARRIER NWO 628.011.212China Scholarship Council scholarship 201906540036STRaTegy STW 14930The Hanarth Funds Foundation for Leonard WeeTRAIN NWO 629.002.212
6 · The paper itself

Abstract

backgroundAs a means to extract biomarkers from medical imaging, radiomics has attracted increased attention from researchers. However, reproducibility and performance of radiomics in low-dose CT scans are still poor, mostly due to noise. Deep learning generative models can be used to denoise these images and in turn improve radiomics' reproducibility and performance. However, most generative models are trained on paired data, which can be difficult or impossible to collect. PURPOSE: In this article, we investigate the possibility of denoising low-dose CTs using cycle generative adversarial networks (GANs) to improve radiomics reproducibility and performance based on unpaired datasets. METHODS AND MATERIALS: Two cycle GANs were trained: (1) from paired data, by simulating low-dose CTs (i.e., introducing noise) from high-dose CTs and (2) from unpaired real low dose CTs. To accelerate convergence, during GAN training, a slice-paired training strategy was introduced. The trained GANs were applied to three scenarios: (1) improving radiomics reproducibility in simulated low-dose CT images and (2) same-day repeat low dose CTs (RIDER dataset), and (3) improving radiomics performance in survival prediction. Cycle GAN results were compared with a conditional GAN (CGAN) and an encoder-decoder network (EDN) trained on simulated paired data.

resultsThe cycle GAN trained on simulated data improved concordance correlation coefficients (CCC) of radiomic features from 0.87 (95%CI, [0.833,0.901]) to 0.93 (95%CI, [0.916,0.949]) on simulated noise CT and from 0.89 (95%CI, [0.881,0.914]) to 0.92 (95%CI, [0.908,0.937]) on the RIDER dataset, as well improving the area under the receiver operating characteristic curve (AUC) of survival prediction from 0.52 (95%CI, [0.511,0.538]) to 0.59 (95%CI, [0.578,0.602]). The cycle GAN trained on real data increased the CCCs of features in RIDER to 0.95 (95%CI, [0.933,0.961]) and the AUC of survival prediction to 0.58 (95%CI, [0.576,0.596]).

conclusionThe results show that cycle GANs trained on both simulated and real data can improve radiomics' reproducibility and performance in low-dose CT and achieve similar results compared to CGANs and EDNs.

Indexed as

Image Processing, Computer-AssistedTomography, X-Ray ComputedHumansReproducibility of Resultscomputed tomographycycle GANdenoisingradiomicsreproducibility

Identifiers

PMID35906893
PMCPMC9588275

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.