Evidence map›Paper›PMID 35902856›Full record

ArticleBMC musculoskeletal disorders2022

Stress distribution patterns during the gait cycle in patients with anterior femoral notching following total knee replacement.

Jin-Cheng Zhang, Le-Shu Zhang, Hang Zhou, Wang Chen, Zheng-Hao Hu, Xiang-Yang Chen, Shuo Feng

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jin-Cheng ZhangDepartment of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, 221002, Xuzhou, Jiangsu, China.
Le-Shu ZhangDepartment of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, 221002, Xuzhou, Jiangsu, China.
Hang ZhouDepartment of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, 221002, Xuzhou, Jiangsu, China.
Wang ChenDepartment of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, 221002, Xuzhou, Jiangsu, China.
Zheng-Hao HuDepartment of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, 221002, Xuzhou, Jiangsu, China.
Xiang-Yang ChenDepartment of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, 221002, Xuzhou, Jiangsu, China. xzchenxiangyang@163.com.
Shuo FengDepartment of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, 221002, Xuzhou, Jiangsu, China. xzfs0561@163.com.

Funding

the Jiangsu Commission of Health LX2021010
6 · The paper itself

Abstract

backgroundAnterior femoral notching (AFN) is a severe complication of total knee replacement (TKR), which in a percentage of patients may lead to fractures after surgery. The purpose of this study was to investigate the stress distribution in patients with AFN and the safety depth of AFN during the gait cycle.

methodsWe performed a finite element (FE) analysis to analyse the mechanics around the femur during the gait cycle in patients with AFN. An adult volunteer was selected as the basis of the model. The TKR models were established in the 3D reconstruction software to simulate the AFN model during the TKR process, and the 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm AFN models were established, after which the prosthesis was assembled. Three key points of the gait cycle (0°, 22°, and 48°) were selected for the analysis.

resultsThe stress on each osteotomy surface was stable in the 0° phase. In the 22° phase, the maximum equivalent stress at 3 mm was observed. In the 48° phase, with the increase in notch depth, each osteotomy surface showed an overall increasing trend, the stress range was more extended, and the stress was more concentrated. Moreover, the maximum equivalent force value (158.3 MPa) exceeded the yield strength (115.1 MPa) of the femur when the depth of the notch was ≥ 3 mm.

conclusionsDuring the gait cycle, if there is an anterior femoral cortical notch ≥ 3 mm, the stress will be significantly increased, especially at 22° and 48°. The maximum equivalent stress exceeded the femoral yield strength and may increase the risk of periprosthetic fractures.

Indexed as

Arthroplasty, Replacement, KneePeriprosthetic FracturesAdultFemurFinite Element AnalysisGaitHumansAnterior femoral notchingBiomechanicsFinite element analysisGait cycleTotal knee replacement

Identifiers

PMID35902856
PMCPMC9330681

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.