ArticleSensors (Basel, Switzerland)2022
Comparative In Situ Study of Dynamic Load Generated by Gravel Piles Measured by a Fiber-Optic Interferometer.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Currently, all the technology used for seismic monitoring is based on sensors in the electrical domain. There are, however, other physical principles that may enable and fully replace existing devices in the future. This paper introduces one of these approaches, namely the field of fiber optics, which has great potential to be fully applied in the field of vibration measurement. The proposed solution uses a Michelson fiber-optic interferometer designed without polarization fading and with an operationally passive demodulation technique using three mutually phase-shifted optical outputs. Standard instrumentation commonly used in the field of seismic monitoring in geotechnical engineering was used as a reference. Comparative measurements were carried out during the implementation of gravel piles, which represents a significant source of vibration. For the correlation of the data obtained, the linear dependence previously verified in laboratory measurements was used. The presented results show that the correlation is also highly favorable (correlation coefficient in excess of 0.9) from the values measured in situ, with an average deviation for the oscillation velocity amplitude of the optical sensor not exceeding 0.0052.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.