ArticleSensors (Basel, Switzerland)2022

Adaptive Motion Artifact Reduction in Wearable ECG Measurements Using Impedance Pneumography Signal.

Xiang An, Yanzhong Liu, Yixin Zhao, Sichao Lu, George K Stylios, Qiang Liu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. ECG-Based Semi-Supervised Anomaly Detection for Early Detection and Monitoring of Epileptic Seizures.International journal of environmental research and public health · 2023
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xiang AnAcademy of Artificial Intelligence, Beijing Institute of Petrochemical Technology, Beijing 102617, China.
Yanzhong LiuAcademy of Artificial Intelligence, Beijing Institute of Petrochemical Technology, Beijing 102617, China.
Yixin ZhaoAcademy of Artificial Intelligence, Beijing Institute of Petrochemical Technology, Beijing 102617, China.ORCID 0000-0002-3164-4015
Sichao LuAcademy of Artificial Intelligence, Beijing Institute of Petrochemical Technology, Beijing 102617, China.
George K StyliosResearch Institute for Flexible Materials, School of Textiles and Design, Heriot-Watt University, Galashiels TD1 3HF, UK.ORCID 0000-0002-7911-1058
Qiang LiuAcademy of Artificial Intelligence, Beijing Institute of Petrochemical Technology, Beijing 102617, China.ORCID 0000-0003-3699-5858

Funding

Beijing Municipal Education Commission, China 22019821001Climbing Program Foundation from Beijing Institute of Petrochemical Technology BIPTAAI-2021-002
6 · The paper itself

Abstract

Noise is a common problem in wearable electrocardiogram (ECG) monitoring systems because the presence of noise can corrupt the ECG waveform causing inaccurate signal interpretation. By comparison with electromagnetic interference and its minimization, the reduction of motion artifact is more difficult and challenging because its time-frequency characteristics are unpredictable. Based on the characteristics of motion artifacts, this work uses adaptive filtering, a specially designed ECG device, and an Impedance Pneumography (IP) data acquisition system to combat motion artifacts. The newly designed ECG-IP acquisition system maximizes signal correlation by measuring both ECG and IP signals simultaneously using the same pair of electrodes. Signal comparison investigations between ECG and IP signals under five different body motions were carried out, and the Pearson Correlation Coefficient |r| was higher than 0.6 in all cases, indicating a good correlation. To optimize the performance of adaptive motion artifact reduction, the IP signal was filtered to a 5 Hz low-pass filter and then fed into a Recursive Least Squares (RLS) adaptive filter as a reference input signal. The performance of the proposed motion artifact reduction method was evaluated subjectively and objectively, and the results proved that the method could suppress the motion artifacts and achieve minimal distortion to the denoised ECG signal.

Indexed as

ArtifactsWearable Electronic DevicesAlgorithmsElectric ImpedanceElectrocardiographyMotionSignal Processing, Computer-Assistedadaptive filteringelectrocardiogramimpedance pneumographymotion artifact reduction

Identifiers

PMID35897997
PMCPMC9332869

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.