Evidence map›Paper›PMID 35897530›Full record

ArticleMaterials (Basel, Switzerland)2022

Effect of Ultrasonic Surface Mechanical Attrition Treatment-Induced Nanograins on the Mechanical Properties and Biocompatibility of Pure Titanium.

Furqan Ahmed, Muhammad Zain-Ul-Abdein, Iftikhar Ahmed Channa, Muhammad Kamran Yaseen, Sadaf Jamal Gilani, Muhammad Atif Makhdoom, Muhammad Mansoor, Usman Shahzad, May Nasser Bin Jumah

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Furqan AhmedDepartment of Metallurgical and Materials Engineering (MME), University of Engineering and Technology (UET), Lahore 54890, Pakistan.
Muhammad Zain-Ul-AbdeinDepartment of Metallurgical and Materials Engineering (MME), University of Engineering and Technology (UET), Lahore 54890, Pakistan.
Iftikhar Ahmed ChannaThin Film Lab, Department of Metallurgical Engineering, NED University of Engineering & Technology, Karachi 75270, Pakistan.ORCID 0000-0002-5585-8886
Muhammad Kamran YaseenDepartment of Metallurgical and Materials Engineering (MME), University of Engineering and Technology (UET), Lahore 54890, Pakistan.
Sadaf Jamal GilaniDepartment of Basic Health Sciences, Preparatory Year, Princess Nourah Bint Abdulrahman University, Riyadh 11671, Saudi Arabia.
Muhammad Atif MakhdoomInstitute of Metallurgy and Materials, University of the Punjab, Lahore 54590, Pakistan.ORCID 0000-0001-7408-0689
Muhammad MansoorInstitute of Industrial Control Systems, Rawalpindi 46000, Pakistan.
Usman ShahzadMaterials Engineering Division, Consulting Services Department, Saudi Aramco, Dhahran 31311, Saudi Arabia.
May Nasser Bin JumahBiology Department, College of Science, Princess Nourah Bint Abdulrahman University, Riyadh 11671, Saudi Arabia.ORCID 0000-0002-3017-9924
University of Engineering and Technology Lahore · PKPrincess Nourah bint Abdulrahman University · SANED University of Engineering and Technology · PKSaudi Aramco (Saudi Arabia) · SAUniversity of the Punjab · PK

Funding

Princess Nourah bint Abdulrahman University PNURSP2022R108
6 · The paper itself

Abstract

Commercially pure titanium (Ti) is widely used in bio-implants due to its high corrosion resistance. However, Ti exhibits marginally low mechanical and tribological properties, which limit its applications in some orthopedic implants. In this work, the Ti samples were subjected to ultrasonic surface mechanical attrition treatment (SMAT) for various durations to improve their surface properties such as hardness, strength and surface energy. SMAT-induced grain refinement was analyzed using optical, scanning electron and atomic force microscopy techniques. A Vickers hardness test was performed to determine the through-thickness hardness. Mechanical testing was carried out to measure the yield strength, ultimate tensile strength and ductility of the specimens. Corrosion tests were performed on a Gamry Potentiostat. The surface energy of SMAT-modified samples was calculated using the Owens-Wendt method. It was observed that SMAT reduced the average grain size from 50 μm to as low as 100 nm. The grain refinement and the corresponding grain boundary density led to a significant improvement in mechanical properties and biocompatibility in terms of increased hardness, yield and tensile strengths, surface energy, corrosion rate and hydrophilicity.

Indexed as

biocompatibilitymechanical propertiesnanograinssurface mechanical attrition treatmenttitanium

Identifiers

PMID35897530
PMCPMC9332258
OpenAlexW4287010258

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.