Evidence map›Paper›PMID 35895744›Full record

ArticlePloS one2022

Primary stability of multi-hole cups compared to plate osteosynthesis in osteoporotic anterior column and posterior hemi-transverse acetabular fractures-A biomechanical comparison.

Andreas Höch, Rebekka Reise, Philipp Pieroh, Christoph-Eckhard Heyde, Johannes Karl Maria Fakler, Stefan Schleifenbaum

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Andreas HöchDepartment of Orthopaedic Surgery, Traumatology and Plastic Surgery, University of Leipzig Medical Center, Leipzig, Germany.
Rebekka ReiseDepartment of Orthopaedic Surgery, Traumatology and Plastic Surgery, University of Leipzig Medical Center, Leipzig, Germany.ORCID 0000-0002-3922-6547
Philipp PierohDepartment of Orthopaedic Surgery, Traumatology and Plastic Surgery, University of Leipzig Medical Center, Leipzig, Germany.
Christoph-Eckhard HeydeDepartment of Orthopaedic Surgery, Traumatology and Plastic Surgery, University of Leipzig Medical Center, Leipzig, Germany.
Johannes Karl Maria FaklerDepartment of Orthopaedic Surgery, Traumatology and Plastic Surgery, University of Leipzig Medical Center, Leipzig, Germany.
Stefan SchleifenbaumDepartment of Orthopaedic Surgery, Traumatology and Plastic Surgery, University of Leipzig Medical Center, Leipzig, Germany.
Leipzig University of Applied Sciences · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAcetabular fractures pose high demands on the surgeon and in the case of osteosynthetic treatment, anatomical reconstruction has the highest priority to achieve a good outcome. However, especially in older patients with poor bone quality, even anatomical reconstruction is no guarantee for a good clinical outcome and may nevertheless end in early osteoarthritis. Primary arthroplasty therefore has an increasing importance in the treatment of these patients. The aim of this study was to biomechanically compare fracture gap displacement and failure load as an assessment measure of the primary stability of conventional plate osteosynthesis with the treatment using a sole multi-hole cup for acetabular fractures.

methodsSix hemi-pelvises each with anterior column and posterior hemi-transverse (ACPHT) fracture were treated with either plate osteosynthesis or a multi-hole cup. The tests were carried out in a standardised test set-up with cyclic loading in various stages between 150 N and 2500 N. The fracture gap displacement was recorded with optical 3D measuring and the failure load was determined after the cyclic measurement.

resultsWith increasing force, the fracture gap displacement increased in both procedures. In each group there was one treatment which failed at the cyclic loading test and a bone fragment was broken out. The primary stability in arthroplasty was comparable to that of the standard osteosynthesis.

conclusionsThe results found seem promising that the primary arthroplasty with a sole multi-hole cup and corresponding screw fixation achieves an initial stability comparable to osteosynthesis for typical ACPHT fractures. However, further clinical studies are needed to prove that the cups heal solidly into the bone.

Indexed as

Fractures, BoneHip FracturesSpinal FracturesAcetabulumAgedBiomechanical PhenomenaBone PlatesBone ScrewsFracture Fixation, InternalHumans

Identifiers

PMID35895744
PMCPMC9328528
OpenAlexW4288052022

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.