Healing Abutment Distortion in Implant Prostheses: An In Vitro Study.

Chandrashekhar Pandey, Bishwa Prakash Bhattarai, Apiwat Riddhabhaya, Natthamet Wongsirichat, Dinesh Rokaya

Open access · goldAbstract read
In one paragraph

Article in Journal of functional biomaterials, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Observational
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Chandrashekhar PandeyDepartment of Clinical Dentistry, International College of Dentistry, Walailak University, Bangkok 10400, Thailand.ORCID 0000-0002-1181-7513
Bishwa Prakash BhattaraiDepartment of Clinical Dentistry, International College of Dentistry, Walailak University, Bangkok 10400, Thailand.ORCID 0000-0003-3359-9032
Apiwat RiddhabhayaDepartment of Oral Biosciences, International College of Dentistry, Walailak University, Bangkok 10400, Thailand.
Natthamet WongsirichatDepartment of Clinical Dentistry, International College of Dentistry, Walailak University, Bangkok 10400, Thailand.
Dinesh RokayaDepartment of Clinical Dentistry, International College of Dentistry, Walailak University, Bangkok 10400, Thailand.ORCID 0000-0002-3854-667X
Walailak University · TH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Little has been studied regarding the repeated usage of healing abutments and their effects on the distortion of dental implant-healing abutment hex surfaces. Additionally, implant manufacturers do not provide specific guidelines on how many times a healing abutment can be used before discarding. Therefore, we evaluated the effect of repeated screwing-unscrewing of implant-healing abutment on the healing abutment hex surface and screw head. A total of 12 Biomate implants with 4 mm diameter and 13 mm length were inserted into a synthetic bone block. The standard healing abutments of 3 mm diameter and 4 mm length were screwed onto each implant using a torque ratchet at a final torque of 30 Ncm. Immediately, the abutments were unscrewed at 30 Ncm. Then, screwing-unscrewing was repeated for 4, 8, 16, 24, 32, 40, 80, 160, 320, and 400 times and the healing abutments were scanned under the scanning electron microscope for any distortion. Distortion was graded as 0, 1, 2, and 3. Data were analyzed using SPSS 24.0. Descriptive statistics were calculated. One-way ANOVA with post hoc using Tukey’s HSD test was performed to analyze the difference in distortion at different screwing-unscrewing times. A significant level was selected at p-value = 0.05. It was found that distortion healing abutments screws were seen after 32 times screwing and unscrewing. There was a significant difference in the distortion (p-value < 0.05) after 24 times of repeated usage of healing abutment and at 160, 320, and 400 times. No surface distortions were observed at the healing abutment screw head at 4, 8, 16, 24, 32, 40, 80, 160, 320, and 400 cycles of screwing-unscrewing. It can be concluded that repeated screwing and unscrewing of the implant-healing abutments causes damage to the healing abutment hex surface. The distortion of healing abutments screws was seen after 32 times screwing and unscrewing. No surface distortions were observed on the healing abutment screw head until 400 times of screwing and unscrewing. Hence, the clinician should be cautious while using the healing abutments repeatedly.

Indexed as

dental implantsdistortionhealing abutmentimplant abutmentscanning electron microscopescrew headscrew threadwear

Identifiers

PMID35893453
PMCPMC9326645
OpenAlexW4283261525

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.