ArticleJournal of personalized medicine2022
Surgeon Dominated Design Can Improve the Accuracy of Patient-Specific Instruments in Kinematically Aligned TKA.
Article in Journal of personalized medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it.
- No difference between CT- and MRI-based patient-specific instrumentation for total knee arthroplasty: an updated systematic review and meta-analysis.Frontiers in bioengineering and biotechnology · 2025Pooled it
- Development and Validation of an Artificial Intelligence Preoperative Planning and Patient-Specific Instrumentation System for Total Knee Arthroplasty.Bioengineering (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Precise bone resection is mandatory for kinematically aligned total knee arthroplasty (KA-TKA). This study is to investigate whether surgeon-dominated design can alter the accuracy of patient-specific instrumentation (PSI) in KA-TKA compared with the engineer design. A total of 24 patients (24 knees) who underwent KA-TKA in our institution were assigned to an engineer design group (10 knees) and surgeon design group (14 knees) chronologically. A novel portable medical-engineer interactive application can greatly enhance the surgeon's participation in PSI design. The bone resection discrepancies were used to evaluate the accuracy of PSI in bone resection. The overall discrepancy of bone resection was reduced by surgeon-designed PSI compared to engineer-designed PSI by 0.33 mm. Surgeon-designed PSI seems to reduce the outliers in terms of relative discrepancies in bone resection as well, but it does not reach statistical significance. Moreover, surgeon-designed PSI could significantly improve the accuracy of PSI in the restoration of the joint line in terms of medial proximal tibial angle and mechanical lateral distal femoral angle. This study indicates that the dominance of surgeons in both PSI design and subsequent surgical operation should be emphasized in efforts to improve the accuracy of PSI.