ArticleBioengineering (Basel, Switzerland)2022
A Computationally Efficient Approach to Simulate Heart Rate Effects Using a Whole Human Heart Model.
Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Developing cardiac biomechanical models beyond the clinic: modeling stressors of daily life.Biomechanics and modeling in mechanobiology · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 3 institutions in 1 country.
Funding
Abstract
Computational modeling of the whole human heart has become a valuable tool to evaluate medical devices such as leadless pacemakers, annuloplasty rings and left ventricular assist devices, since it is often difficult to replicate the complex dynamic interactions between the device and human heart in bench-top and animal tests. The Dassault Systèmes Living Heart Human Model (LHHM) is a finite-element model of whole-human-heart electromechanics that has input parameters that were previously calibrated to generate physiological responses in a healthy heart beating at 60 beat/min (resting state). This study demonstrates that, by adjusting only six physiologically meaningful parameters, the LHHM can be recalibrated to generate physiological responses in a healthy heart beating at heart rates ranging from 90−160 beat/min. These parameters are as follows: the sinoatrial node firing period decreases from 0.67 s at 90 bpm to 0.38 s at 160 bpm, atrioventricular delay decreases from 0.122 s at 90 bpm to 0.057 s at 160 bpm, preload increases 3-fold from 90 bpm to 160 bpm, body resistance at 160 bpm is 80% of that at 90 bpm, arterial stiffness at 160 bpm is 3.9 times that at 90 bpm, and a parameter relating myofiber twitch force duration and sarcomere length decreases from 238 ms/mm at 90 bpm to 175 ms/mm at 160 bpm. In addition, this study demonstrates the feasibility of using the LHHM to conduct clinical investigations in AV delay optimization and hemodynamic differences between pacing and exercise. AV delays in the ranges of 40 ms to 250 ms were simulated and stroke volume and systolic blood pressure showed clear peaks at 120 ms for 90 bpm. For a heart during exercise, the increase in cardiac output continues to 160 bpm. However, for a heart during pacing, those physiological parameter adjustments are removed that are related to changes in body oxygen requirements (preload, arterial stiffness and body resistance). Consequently, cardiac output increases initially with heart rate; as the heart rate goes up (>100 bpm), the increasing rate of cardiac output slows down and approaches a plateau.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.