Evidence map›Paper›PMID 35892034›Full record

ArticleBiomedical engineering letters2022

MCU-less biphasic electrical stimulation circuit for miniaturized neuromodulator.

Himshekhar Das, Hangue Park

Abstract read
In one paragraph

Article in Biomedical engineering letters, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Himshekhar DasElectrical and Computer Engineering, Texas A & M University, College Station, USA.
Hangue ParkElectrical and Computer Engineering, Texas A & M University, College Station, USA.ORCID 0000-0001-8641-2695

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A standalone neuro-stimulator circuit without a need of microcontroller (MCU) is presented. The neuro-stimulator circuit has a capability to produce a biphasic electrical stimulus with programmable pulse width and train duration. The proposed hardware system consists of commercial-off-the-shelf (COTS) components: a comparator to recognize triggering events and generate on/off signal for a variable train duration, a programmable timer to generate oscillatory signal with a fixed frequency and a variable pulse width, and a differentiator to convert monophasic pulses to biphasic pulses. The differentiator also works as a current driver having current drive capability of up to 40 mA. The proposed MCU-less biphasic electrical neuro-stimulator successfully generated biphasic stimuli with variable pulse widths from 400 µs to 5 ms and train durations from 35 to 55% of cycle duration. It works with fixed parameters programmed at the beginning, and does not need continuous MCU input. Therefore, the proposed standalone neuro-stimulator circuit has a potential to decrease power and area consumption and minimize the size of the neuro-stimulator system.

Indexed as

Digitally programmableMCU-lessNeuro-stimulatorPower efficientStandalone stimulator

Identifiers

PMID35892034
PMCPMC9308854

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.