Evidence map›Paper›PMID 35892029›Full record

ReviewBiomedical engineering letters2022

Silicon photomultiplier signal readout and multiplexing techniques for positron emission tomography: a review.

Haewook Park, Minseok Yi, Jae Sung Lee

Open access · hybridAbstract readReview
In one paragraph

Review in Biomedical engineering letters, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
13.8field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 57 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Time to shift to Digital PET/CT?Nuclear medicine and molecular imaging · 2025
    Article
  7. Article
  8. Review
  9. Review
  10. Review
  11. PET Detectors Based on Multi-Resolution SiPM Arrays.IEEE transactions on radiation and plasma medical sciences · 2024
    Article
  12. Characterization of external optical crosstalk reduction for SiPM-based scintillation detectors with an optical bandpass filter.Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment · 2024
    Article
  13. Article
  14. Article
  15. Decision Tree-Based Demultiplexing for Prism-PET.IEEE transactions on nuclear science · 2023
    Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 3 countries.

Haewook ParkDepartment of Biomedical Sciences, Seoul National University College of Medicine, Seoul, 03080 South Korea.
Minseok YiDepartment of Nuclear Medicine, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul, 03080 South Korea.
Jae Sung LeeDepartment of Biomedical Sciences, Seoul National University College of Medicine, Seoul, 03080 South Korea.ORCID 0000-0001-7623-053X
Seoul National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In recent years, silicon photomultiplier (SiPM) is replacing the photomultiplier tube (PMT) in positron emission tomography (PET) systems due to its superior properties, such as fast single-photon timing response, small gap between adjacent photosensitive pixels in the array, and insensitivity to magnetic fields. One of the technical challenges when developing SiPM-based PET systems or other position-sensitive radiation detectors is the large number of output channels coming from the SiPM array. Therefore, various signal multiplexing methods have been proposed to reduce the number of output channels and the load on the subsequent data acquisition (DAQ) system. However, the large PN-junction capacitance and quenching resistance of the SiPM yield undesirable resistance-capacitance delay when multiple SiPMs are combined, which subsequently causes the accumulation of dark counts and signal fluctuation of SiPMs. Therefore, without proper SiPM signal handling and processing, the SiPMs may yield worse timing characteristics than the PMTs. This article reviews the evolution of signal readout and multiplexing methods for the SiPM. In this review, we focus primarily on analog electronics for SiPM signal multiplexing, which allows for the reduction of DAQ channels required for the SiPM-based position-sensitive detectors used in PET and other radiation detector systems. Although the applications of most technologies described in the article are not limited to PET systems, the review highlights efforts to improve the physical performance (e.g. spatial, energy, and timing resolutions) of PET detectors and systems.

Indexed as

MultiplexingPositron emission tomography (PET)Radiation detectorSilicon photomultiplier (SiPM)Time-of-flight (TOF)

Identifiers

PMID35892029
PMCPMC9308856
OpenAlexW4285588055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.