ArticleSensors (Basel, Switzerland)2022
Design of the Automated Calibration Process for an Experimental Laser Inspection Stand.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 12 citations in OpenAlex.
- Autoencoders Based on 2D Convolution Implemented for Reconstruction Point Clouds from Line Laser Sensors.Sensors (Basel, Switzerland) · 2023Article
- Polarization Calibration of a Microwave Polarimeter with Near-Infrared Up-Conversion for Optical Correlation and Detection.Sensors (Basel, Switzerland) · 2022Article
- Modal Analysis Using Digital Image Correlation Technique.Materials (Basel, Switzerland) · 2022Article
- A High-Sensitivity Gravimetric Biosensor Based on SSensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
Abstract
This paper deals with the concept of the automated calibration design for inspection systems using laser sensors. The conceptual solution is based on using a laser sensor and its ability to scan 3D surfaces of inspected objects in order to create a representative point cloud. Problems of scanning are briefly discussed. The automated calibration procedure for solving problems of errors due to non-precise adjustment of the mechanical arrangement, possible tolerances in assembly, and their following elimination is proposed. The main goal is to develop a system able to measure and quantify the quality of produced objects in the environment of Industry 4.0. Laboratory measurements on the experimental stand, including the principal software solution for automated calibration of laser sensors suitable for gear wheel inspection systems are presented. There is described design of compensation eccentricity by Fourier transform and sinusoidal fitting to identify and suppress the first harmonic component in the data with high precision measuring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.