Evidence map›Paper›PMID 35890969›Full record

ArticleSensors (Basel, Switzerland)2022

Criterion Validity of Linear Accelerations Measured with Low-Sampling-Frequency Accelerometers during Overground Walking in Elderly Patients with Knee Osteoarthritis.

Arash Ghaffari, Ole Rahbek, Rikke Emilie Kildahl Lauritsen, Andreas Kappel, Søren Kold, John Rasmussen

Registry-linked trialAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05992064 (Investigating the Potential of Wearable Sensors for Monitoring the Postoperative Recovery of Total Knee Arthroplasty Patients), which is not on this map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05992064 recruitingnot on this mapstarted 2024, after this paper: background citation

Investigating the Potential of Wearable Sensors for Monitoring the Postoperative Recovery of Total Knee Arthroplasty Patients: A Protocol for Prospective Longitudinal Observational Study

TypeobservationalSponsorAalborg University HospitalRan2024 to 2026Enrolled30ConditionsArthroplasty, Replacement, KneeArmsMeasuring gait
3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Monitoring Gait Recovery After Total Knee Arthroplasty Using Wearable Sensors: Responsiveness of Gait Accelerations.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025
    Observational
  3. Article
  4. Article
  5. Article
  6. Article
  7. Observational
  8. Article
  9. Observational
  10. Outdoor Kindergartens: A Structural Way to Improve Early Physical Activity Behaviour?International journal of environmental research and public health · 2023
    Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Arash GhaffariInterdisciplinary Orthopaedics, Aalborg University Hospital, 9000 Aalborg, Denmark.ORCID 0000-0002-6901-0763
Ole RahbekInterdisciplinary Orthopaedics, Aalborg University Hospital, 9000 Aalborg, Denmark.ORCID 0000-0002-5602-4533
Rikke Emilie Kildahl LauritsenInterdisciplinary Orthopaedics, Aalborg University Hospital, 9000 Aalborg, Denmark.
Andreas KappelInterdisciplinary Orthopaedics, Aalborg University Hospital, 9000 Aalborg, Denmark.ORCID 0000-0001-8385-3567
Søren KoldInterdisciplinary Orthopaedics, Aalborg University Hospital, 9000 Aalborg, Denmark.ORCID 0000-0002-3387-1473
John RasmussenDepartment of Materials and Production, Aalborg University, 9220 Aalborg East, Denmark.ORCID 0000-0003-3257-5653

Funding

The Research Fund of Danish Health Region North 2021-0019
6 · The paper itself

Abstract

Sensors with a higher sampling rate produce higher-quality data. However, for more extended periods of data acquisition, as in the continuous monitoring of patients, the handling of the generated big data becomes increasingly complicated. This study aimed to determine the validity and reliability of low-sampling-frequency accelerometer (SENS) measurements in patients with knee osteoarthritis. Data were collected simultaneously using SENS and a previously validated sensor (Xsens) during two repetitions of overground walking. The processed acceleration signals were compared with respect to different coordinate axes to determine the test-retest reliability and the agreement between the two systems in the time and frequency domains. In total, 44 participants were included. With respect to different axes, the interclass correlation coefficient for the repeatability of SENS measurements was [0.93-0.96]. The concordance correlation coefficients for the two systems' agreement were [0.81-0.91] in the time domain and [0.43-0.99] in the frequency domain. The absolute biases estimated by the Bland-Altman method were [0.0005-0.008] in the time domain and [0-0.008] in the frequency domain. Low-sampling-frequency accelerometers can provide relatively valid data for measuring the gait accelerations in patients with knee osteoarthritis and can be used in the future for remote patient monitoring.

Indexed as

Osteoarthritis, KneeAccelerationAccelerometryAgedBiomechanical PhenomenaGaitHumansReproducibility of ResultsWalkingfrequency-domain comparisongait accelerationsinertial measurement unitsknee osteoarthritislow-sampling-frequency accelerometersremote monitoring of patientsSENS sensorstest–retest reliabilitytime-domain comparisonwearable motion-tracking sensors

Identifiers

PMID35890969
PMCPMC9322915

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.