Evidence map›Paper›PMID 35890942›Full record

ArticleSensors (Basel, Switzerland)2022

Built-In Packaging for Single Terminal Devices.

Ahmet Gulsaran, Bersu Bastug Azer, Samed Kocer, Sasan Rahmanian, Resul Saritas, Eihab M Abdel-Rahman, Mustafa Yavuz

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ahmet GulsaranMechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Bersu Bastug AzerMechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, ON N2L 3G1, Canada.ORCID 0000-0002-0344-9634
Samed KocerWaterloo Institute for Nanotechnology (WIN), University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Sasan RahmanianSystems Design Engineering Department, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Resul SaritasWaterloo Institute for Nanotechnology (WIN), University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Eihab M Abdel-RahmanWaterloo Institute for Nanotechnology (WIN), University of Waterloo, Waterloo, ON N2L 3G1, Canada.ORCID 0000-0002-3709-7593
Mustafa YavuzMechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, ON N2L 3G1, Canada.

Funding

CMC Microsystems (Canada) 9844Mitacs IT17161, 2000- 2024Natural Sciences and Engineering Research Council ALLRP 554872 - 20Natural Sciences and Engineering Research Council GPIN-2020-06053
6 · The paper itself

Abstract

An alternative packaging method, termed built-in packaging, is proposed for single terminal devices, and demonstrated with an actuator application. Built-in packaging removes the requirements of wire bonding, chip carrier, PCB, probe station, interconnection elements, and even wires to drive single terminal devices. Reducing these needs simplifies operation and eliminates possible noise sources. A micro resonator device is fabricated and built-in packaged for demonstration with electrostatic actuation and optical measurement. Identical actuation performances are achieved with the most conventional packaging method, wire bonding. The proposed method offers a compact and cheap packaging for industrial and academic applications.

Indexed as

actuator applicationMEMSmicro resonatorNEMSpackagingsensor applicationwire bonding

Identifiers

PMID35890942
PMCPMC9318481

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.