ArticleSensors (Basel, Switzerland)2022
Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 13 citations in OpenAlex.
- Muscle oxygenation measured by near-infrared spectroscopy during resistance training: A scoping review.Physiological reports · 2026Article
- Distinguishing Muscle Oxygen Saturation from Tissue Oxygen Saturation: Accuracy, Limitations, and Practical Utility in Muscle Oximetry.Sports medicine - open · 2026Article
- Near-Infrared Spectroscopy Allows for Monitoring of Bone Fracture Healing via Changes in Oxygenation.Journal of functional biomaterials · 2024Article
- Optimizing brain protection after cardiac arrest: advanced strategies and best practices.Interface focus · 2024Review
- Reliability and Convergent Validity of Endurance Indices Derived from Near-Infrared Spectroscopy and Electromyography during a Bilateral Hanging Task in Amateur Rock Climbers.Journal of functional morphology and kinesiology · 2024Article
- A short review of application of near-infrared spectroscopy (NIRS) for the assessment of microvascular post-occlusive reactive hyperaemia (PORH) in skeletal muscle.Frontiers in physiology · 2024Review
- Effects of occlusion pressure on hemodynamic responses recorded by near-infrared spectroscopy across two visits.Frontiers in physiology · 2024Article
- Association between Fractional Oxygen Extraction from Resting Quadriceps Muscle and Body Composition in Healthy Men.Journal of functional morphology and kinesiology · 2023Article
- Evaluation of transcutaneous near-infrared spectroscopy for early detection of cardiac arrest in an animal model.Scientific reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
(1) Background: Near-infrared spectroscopy (NIRS) is an innovative and non-invasive technology used to investigate muscular oxygenation. The aim of this study is to assess the within- and between-session reliability of the NIRS Portamon (Artinis, Elst, Netherlands) device following three sets of induced muscle ischemia. (2) Methods: Depending on the experimental group (G1, G2 or G3), a cuff was inflated three times on the left upper arm to 50 mmHg (G1), systolic blood pressure (SBP) + 50 mmHg (G2) or 250 mmHg (G3). Maximum, minimum and reoxygenation rate values were assessed after each occlusion phase, using a Portamon device placed on the left brachioradialis. Reliability was assessed with intraclass correlation coefficient (ICC) value and ICC 95% confidence interval (CI-95%), coefficient of variation (CV) and standard error of measurement (SEM) (3) Results: Our results showed a good to excellent reliability for maximums and minimums within-session. However, the reoxygenation rate within sessions as well as measurements between sessions cannot predominantly show good reliability. (4) Conclusions: Multiple measurements of maximums and minimums within a single session appeared to be reliable which shows that only one measurement is necessary to assess these parameters. However, it is necessary to be cautious with a comparison of maximum, minimum and reoxygenation rate values between sessions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.