ArticleSensors (Basel, Switzerland)2022
Photoplethysmogram Recording Length: Defining Minimal Length Requirement from Dynamical Characteristics.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Data Reduction Methodology for Dynamic Characteristic Extraction in Photoplethysmogram.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Photoplethysmography is a widely used technique to noninvasively assess heart rate, blood pressure, and oxygen saturation. This technique has considerable potential for further applications-for example, in the field of physiological and mental health monitoring. However, advanced applications of photoplethysmography have been hampered by the lack of accurate and reliable methods to analyze the characteristics of the complex nonlinear dynamics of photoplethysmograms. Methods of nonlinear time series analysis may be used to estimate the dynamical characteristics of the photoplethysmogram, but they are highly influenced by the length of the time series, which is often limited in practical photoplethysmography applications. The aim of this study was to evaluate the error in the estimation of the dynamical characteristics of the photoplethysmogram associated with the limited length of the time series. The dynamical properties were evaluated using recurrence quantification analysis, and the estimation error was computed as a function of the length of the time series. Results demonstrated that properties such as determinism and entropy can be estimated with an error lower than 1% even for short photoplethysmogram recordings. Additionally, the lower limit for the time series length to estimate the average prediction time was computed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.