Evidence map›Paper›PMID 35890785›Full record

ArticleSensors (Basel, Switzerland)2022

Responsivity and NEP Improvement of Terahertz Microbolometer by High-Impedance Antenna.

Arie Pangesti Aji, Hiroaki Satoh, Catur Apriono, Eko Tjipto Rahardjo, Hiroshi Inokawa

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Arie Pangesti AjiGraduate School of Science and Technology, Shizuoka University, Hamamatsu 432-8011, Japan.
Hiroaki SatohResearch Institute of Electronics, Shizuoka University, Hamamatsu 432-8011, Japan.ORCID 0000-0002-5868-0219
Catur AprionoDepartment of Electrical Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia.ORCID 0000-0002-7843-6352
Eko Tjipto RahardjoDepartment of Electrical Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia.
Hiroshi InokawaGraduate School of Science and Technology, Shizuoka University, Hamamatsu 432-8011, Japan.ORCID 0000-0002-8647-3524

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The antenna-coupled microbolometer with suspended titanium heater and thermistor was attractive as a terahertz (THz) detector due to its structural simplicity and low noise levels. In this study, we attempted to improve the responsivity and noise-equivalent power (NEP) of the THz detector by using high-resistance heater stacked on the meander thermistor. A wide range of heater resistances were prepared by changing the heater width and thickness. It was revealed that the electrical responsivity and NEP could be improved by increasing the heater's resistance. To make the best use of this improvement, a high-impedance folded dipole antenna was introduced, and the optical performance at 1 THz was found to be better than that of the conventional halfwave dipole antenna combined with a low-resistance heater. Both the electrical and optical measurement results indicated that the increase in heater resistance could reduce the thermal conductance in the detector, thus improved the responsivity and NEP even if the thermistor resistance was kept the same.

Indexed as

Terahertz RadiationElectric Impedanceantennaelectron beam lithographyfolded dipolehalfwave dipoleheaternoise equivalent powerresponsivityterahertzthermal detectorthermistor

Identifiers

PMID35890785
PMCPMC9324361

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.