Evidence map›Paper›PMID 35889454›Full record

ArticleMolecules (Basel, Switzerland)2022

Electrochemical Immunoassay for Tumor Marker CA19-9 Detection Based on Self-Assembled Monolayer.

Zheng Wei, Xiaoping Cai, Weifeng Cui, Junping Zhang

Abstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Ratiometric electrochemical aptasensor based on functionalized graphene nanocomposites for detection of CA19-9.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2025
    Article
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Zheng WeiCancer Research Institute, Henan Academy Institute of Chinese Medicine, Zhengzhou 450000, China.ORCID 0000-0002-0454-4158
Xiaoping CaiCancer Research Institute, Henan Academy Institute of Chinese Medicine, Zhengzhou 450000, China.
Weifeng CuiCancer Research Institute, Henan Academy Institute of Chinese Medicine, Zhengzhou 450000, China.
Junping ZhangCancer Research Institute, Henan Academy Institute of Chinese Medicine, Zhengzhou 450000, China.

Funding

China Postdoctoral Science Foundation No. 2019T120626Henan TCM Foundation 2019ZYBJ28;20-21ZY1031&ZYZD19National Natural Science Foundation of China No.81873290The Scientific and technological project of Henan Province in China No. 212102310366Young and Middle-aged Academic Leaders of Health in Henan Province 2021-025
6 · The paper itself

Abstract

A CA19-9 electrochemical immunosensor was constructed using a hybrid self-assembled membrane modified with a gold electrode and applied to detect real samples. Hybrid self-assembled membranes were selected for electrode modification and used to detect antigens. First, the pretreated working electrodes were placed in a 3-mercaptopropionic acid (MPA)/β-mercaptoethanol (ME) mixture for 24 h for self-assembly. The electrodes were then placed in an EDC/NHS mixture for 1 h. Layer modification was performed by stepwise dropwise addition of CA19-9 antibody, BSA, and antigen. Differential pulse voltammetry was used to characterize this immunosensor preparation process. The assembled electrochemical immunosensor enables linear detection in the concentration range of 0.05-500 U/mL of CA19-9, and the detection limit was calculated as 0.01 U/mL. The results of the specificity measurement test showed that the signal change of the interfering substance was much lower than the response value of the detected antigen, indicating that the sensor has good specificity and strong anti-interference ability. The repeatability test results showed that the relative standard deviations were less than 5%, showing good accuracy and precision. The CA19-9 electrochemical immunosensor was used for the actual sample detection, and the experimental results of the standard serum addition method showed that the RSD values of the test concentrations were all less than 10%. The recoveries were 102.4-115.0%, indicating that the assay has high precision, good accuracy, and high potential application value.

Indexed as

Biosensing TechniquesCA-19-9 AntigenBiomarkers, TumorElectrochemical TechniquesElectrodesGoldImmunoassayLimit of DetectionBiomarkers, TumorCA-19-9 AntigenGoldCA19-9electrochemical immunosensorgastric cancergold electrodeself-assembled membrane

Identifiers

PMID35889454
PMCPMC9324264

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.