ArticleMolecules (Basel, Switzerland)2022
A Specific HPLC Method to Determine Residual HEPES in [
Article in Molecules (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 17 citations in OpenAlex.
- TheEJNMMI radiopharmacy and chemistry · 2026Article
- Establishment and validation of an alternative automated synthesis of [68Ga]Ga-DOTA-Siglec-9 in an independent laboratory for clinical use.EJNMMI radiopharmacy and chemistry · 2025Article
- Specific reaction conditions for efficient automatedFrontiers in medicine · 2025Article
- Towards Optimal AutomatedJournal of labelled compounds & radiopharmaceuticals · 2024Article
- Validation of a radiosynthesis method and a novel quality control system for [EJNMMI radiopharmacy and chemistry · 2024Article
- [Pharmaceuticals (Basel, Switzerland) · 2024Article
- Aqueous remote loading of model cationic peptides in uncapped poly(lactide-co-glycolide) microspheres for long-term controlled release.Drug delivery and translational research · 2024Article
- Scale down and optimized automated production of [68Ga]68Ga-DOTA-ECL1i PET tracer targeting CCR2 expression.EJNMMI radiopharmacy and chemistry · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Nowadays, in Nuclear Medicine, clinically applied radiopharmaceuticals must meet quality release criteria such as high radiochemical purity and radiochemical yield. Many radiopharmaceuticals do not have marketing authorization and have no dedicated monograph within European Pharmacopeia (Ph. Eur.); therefore, general monographs on quality controls (QCs) have to be applied for clinical application. These criteria require standardization and validation in labeling and preparation, including quality controls measurements, according to well defined standard operation procedures. However, QC measurements are often based on detection techniques that are specific to a certain chromatographic system. Several radiosyntheses of [68Ga]Ga-radiopharmaceuticals are more efficient and robust when they are performed with 2-[4-(2-hydroxyethyl)piperazin-1-yl] ethanesulfonic acid (HEPES) buffer, which is considered as an impurity to be assessed in the QC procedure, prior to clinical use. Thus, Ph. Eur. has introduced a thin-layer chromatography (TLC) method to quantify the HEPES amount that is present in [68Ga]Ga-radiopharmaceuticals. However, this is only qualitative and has proven to be unreliable. Here we develop and validate a new high-performance liquid chromatography (UV-Radio-HPLC) method to quantify the residual amount of HEPES in 68Ga-based radiopharmaceuticals. Method: To validate the proposed UV-Radio-HPLC method, a stepwise approach was used, as defined in the guidance document that was adopted by the European Medicines Agency (CMP/ICH/381/95 2014). The assessed parameters are specificity, linearity, precision (repeatability), accuracy, and limit of quantification. A range of concentrations of HEPES (100, 80, 60, 40, 20, 10, 5, 3 μg/mL) were analyzed. Moreover, to test the validity and pertinence of our new HPLC method, we analyzed samples of [68Ga]Ga-DOTATOC; [68Ga]Ga-PSMA; [68Ga]Ga-DOTATATE; [68Ga]Ga-Pentixafor; and [68Ga]Ga-NODAGA-Exendin-4 from different batches that were prepared for clinical use. Results: In the assessed samples, HEPES could not be detected by the TLC method that was described in Ph. Eur. within 4 min incubation in an iodine-saturated chamber. Our developed HPLC method showed excellent linearity between 3 and 100 μg/mL for HEPES, with a correlation coefficient (R2) for calibration curves that was equal to 0.999, coefficients of variation (CV%) < 2%, and percent deviation value of bias from 100% to 5%, in accordance with acceptance criteria. The intra-day and inter-day precision of our method was statistically confirmed and the limit-of-quantification (LOQ) was 3 μg/mL, confirming the high sensitivity of the method. The amount of HEPES that was detected with our developed HPLC method in the tested [68Ga]Ga-radiopharmaceuticals resulted well below the Ph. Eur. limit, especially for [68Ga]Ga-NODAGA-Exendin-4. Conclusions: The TLC method that is described in Ph. Eur. to assess residual HEPES in [68Ga]-based radiopharmaceuticals may not be sufficiently sensitive and thus unsuitable for QC release. Our new HPLC method was sensitive, quantitative, reproducible, and rapid for QCs, allowing us to exactly determine the residual HEPES amount in [68Ga]Ga-radiopharmaceuticals for safe patient administration.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.