ArticleMicromachines2022
Influence of Electrode Structure on Performance of Laser Direct Writing Cu-PI Flexible Humidity Sensor.
Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Preparation of Dispersed Copper(II) Oxide Nanosuspensions as Precursor for Femtosecond Reductive Laser Sintering by High-Energy Ball Milling.Nanomaterials (Basel, Switzerland) · 2023Article
- Humidity-Sensing Mattress for Long-Term Bedridden Patients with Incontinence-Associated Dermatitis.Micromachines · 2023Article
- Ramie Fabric Treated with Carboxymethylcellulose and Laser Engraved for Strain and Humidity Sensing.Micromachines · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Electrode structure is an essential factor affecting the performance of flexible humidity sensors. In this study, Cu and Cu2 + 1O electrodes were printed by the one-step method using laser direct writing technology to reduce the nano-CuO ink on flexible substrate PI and to be used for a humidity sensor. The resistance of the humidity sensors with nine various electrode structures was measured under the relative humidity (RH) of 16-78%. It was observed that all sensors showed good humidity sensing characteristics, and the sensitivity of the copper-based humidity sensor was not affected by the electrode structure under low humidity conditions but was significant under high humidity conditions. The sensor with the length of 1960 μm and the width of 120 μm shows the lowest sensitivity of 180.2 KΩ/%RH under 35% RH, and the sensor with the length of 2430 μm and the width of 180 μm shows the highest sensitivity of 1744 kΩ/%RH under 65% RH. It is expected that the results can provide an assessment of the performance improvement of the flexible humidity sensor and a reference for the research and development of intelligent wearable devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.