ArticleHealthcare (Basel, Switzerland)2022
Classification of Depressive and Schizophrenic Episodes Using Night-Time Motor Activity Signal.
Article in Healthcare (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.
- The Performance of Wearable Device-Based Artificial Intelligence in Detecting Depression: Systematic Review and Meta-Analysis.JMIR mental health · 2026Pooled it
- Machine learning helps predict early onset psychosis with serum protein biomarkers, neuropsychometry, and clinicodemographic data.Scientific reports · 2025Article
- Passive Sensing for Mental Health Monitoring Using Machine Learning With Wearables and Smartphones: Scoping Review.Journal of medical Internet research · 2025Article
- A new framework for mental illnesses diagnosis using wearable devices aided by improved convolutional neural network.Scientific reports · 2025Article
- Convolutional Neural Network for Depression and Schizophrenia Detection.Diagnostics (Basel, Switzerland) · 2025Article
- Unipolar and Bipolar Depression Detection and Classification Based on Actigraphic Registration of Motor Activity Using Machine Learning and Uniform Manifold Approximation and Projection Methods.Diagnostics (Basel, Switzerland) · 2023Article
- Systematic review and meta-analysis of performance of wearable artificial intelligence in detecting and predicting depression.NPJ digital medicine · 2023Article
- Wearable Artificial Intelligence for Anxiety and Depression: Scoping Review.Journal of medical Internet research · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Major depressive disorder (MDD) is the most recurrent mental illness globally, affecting approximately 5% of adults. Furthermore, according to the National Institute of Mental Health (NIMH) of the U.S., calculating an actual schizophrenia prevalence rate is challenging because of this illness's underdiagnosis. Still, most current global metrics hover between 0.33% and 0.75%. Machine-learning scientists use data from diverse sources to analyze, classify, or predict to improve the psychiatric attention, diagnosis, and treatment of MDD, schizophrenia, and other psychiatric conditions. Motor activity data are gaining popularity in mental illness diagnosis assistance because they are a cost-effective and noninvasive method. In the knowledge discovery in databases (KDD) framework, a model to classify depressive and schizophrenic patients from healthy controls is constructed using accelerometer data. Taking advantage of the multiple sleep disorders caused by mental disorders, the main objective is to increase the model's accuracy by employing only data from night-time activity. To compare the classification between the stages of the day and improve the accuracy of the classification, the total activity signal was cut into hourly time lapses and then grouped into subdatasets depending on the phases of the day: morning (06:00-11:59), afternoon (12:00-17:59), evening (18:00-23:59), and night (00:00-05:59). Random forest classifier (RFC) is the algorithm proposed for multiclass classification, and it uses accuracy, recall, precision, the Matthews correlation coefficient, and F1 score to measure its efficiency. The best model was night-featured data and RFC, with 98% accuracy for the classification of three classes. The effectiveness of this experiment leads to less monitoring time for patients, reducing stress and anxiety, producing more efficient models, using wearables, and increasing the amount of data.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.