Evidence map›Paper›PMID 35884818›Full record

ArticleBiomedicines2022

Assessing Detection Accuracy of Computerized Sonographic Features and Computer-Assisted Reading Performance in Differentiating Thyroid Cancers.

Hao-Chih Tai, Kuen-Yuan Chen, Ming-Hsun Wu, King-Jen Chang, Chiung-Nien Chen, Argon Chen

Open access · goldAbstract read
In one paragraph

Article in Biomedicines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Hao-Chih TaiDepartment of Surgery, National Taiwan University Hospital and College of Medicine, Taipei 100225, Taiwan.
Kuen-Yuan ChenDepartment of Surgery, National Taiwan University Hospital and College of Medicine, Taipei 100225, Taiwan.
Ming-Hsun WuDepartment of Surgery, National Taiwan University Hospital and College of Medicine, Taipei 100225, Taiwan.
King-Jen ChangDepartment of Surgery, National Taiwan University Hospital and College of Medicine, Taipei 100225, Taiwan.
Chiung-Nien ChenDepartment of Surgery, National Taiwan University Hospital and College of Medicine, Taipei 100225, Taiwan.
Argon ChenGraduate Institute of Industrial Engineering, National Taiwan University, Taipei 106216, Taiwan.ORCID 0000-0002-7951-9950
National Taiwan University Hospital · TWNational Taiwan University · TW

Funding

Ministry of Science and Technology Taiwan NSC 100-3114-B-002-004
6 · The paper itself

Abstract

For ultrasound imaging of thyroid nodules, medical guidelines are all based on findings of sonographic features to provide clinicians management recommendations. Due to the recent development of artificial intelligence and machine learning (AI/ML) technologies, there have been computer-assisted detection (CAD) software devices available for clinical use to detect and quantify the sonographic features of thyroid nodules. This study is to validate the accuracy of the computerized sonographic features (CSF) by a CAD software device, namely, AmCAD-UT, and then to assess how the reading performance of clinicians (readers) can be improved providing the computerized features. The feature detection accuracy is tested against the ground truth established by a panel of thyroid specialists and a multiple-reader multiple-case (MRMC) study is performed to assess the sequential reading performance with the assistance of the CSF. Five computerized features, including anechoic area, hyperechoic foci, hypoechoic pattern, heterogeneous texture, and indistinct margin, were tested, with AUCs ranging from 0.888~0.946, 0.825~0.913, 0.812~0.847, 0.627~0.77, and 0.676~0.766, respectively. With the five CSFs, the sequential reading performance of 18 clinicians is found significantly improved, with the AUC increasing from 0.720 without CSF to 0.776 with CSF. Our studies show that the computerized features are consistent with the clinicians' findings and provide additional value in assisting sonographic diagnosis.

Indexed as

computer-assisted detectionMRMC studysonographic featuresthyroid nodules

Identifiers

PMID35884818
PMCPMC9313277
OpenAlexW4283515243

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.