Evidence map›Paper›PMID 35884813›Full record

ArticleBiomedicines2022

Heterogeneous Maturation of Arterio-Venous Fistulas and Loop-Shaped Venous Interposition Grafts: A Histological and 3D Flow Simulation Comparison.

Balazs Szabo, Balazs Gasz, Laszlo Adam Fazekas, Adam Varga, Levente Kiss-Papai, Orsolya Matolay, Zsofia Rezsabek, Mohammad W Al-Smadi, Norbert Nemeth

Abstract read
In one paragraph

Article in Biomedicines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Balazs SzaboDepartment of Operative Techniques and Surgical Research, Faculty of Medicine, University of Debrecen, Moricz Zsigmond u. 22, H-4032 Debrecen, Hungary.ORCID 0000-0002-0078-8614
Balazs GaszDepartment of Surgical Research and Techniques, Faculty of Medicine, University of Pecs, Szigeti u. 12, H-7624 Pecs, Hungary.ORCID 0000-0002-6036-6210
Laszlo Adam FazekasDepartment of Operative Techniques and Surgical Research, Faculty of Medicine, University of Debrecen, Moricz Zsigmond u. 22, H-4032 Debrecen, Hungary.
Adam VargaDepartment of Operative Techniques and Surgical Research, Faculty of Medicine, University of Debrecen, Moricz Zsigmond u. 22, H-4032 Debrecen, Hungary.
Levente Kiss-PapaiDepartment of Surgical Research and Techniques, Faculty of Medicine, University of Pecs, Szigeti u. 12, H-7624 Pecs, Hungary.ORCID 0000-0002-2586-8960
Orsolya MatolayDepartment of Pathology, Faculty of Medicine, University of Debrecen, Nagyerdei krt. 98, H-4032 Debrecen, Hungary.
Zsofia RezsabekDepartment of Operative Techniques and Surgical Research, Faculty of Medicine, University of Debrecen, Moricz Zsigmond u. 22, H-4032 Debrecen, Hungary.
Mohammad W Al-SmadiDepartment of Operative Techniques and Surgical Research, Faculty of Medicine, University of Debrecen, Moricz Zsigmond u. 22, H-4032 Debrecen, Hungary.
Norbert NemethDepartment of Operative Techniques and Surgical Research, Faculty of Medicine, University of Debrecen, Moricz Zsigmond u. 22, H-4032 Debrecen, Hungary.ORCID 0000-0002-1162-3778

Funding

Bridging Fund of the Faculty of Medicine, University of Debrecen 2021Human Resource Development Operational Program of Hungary EFOP-3.6.3-VEKOP-16-2017-00009National Research, Development and Innovation Office NKFI-1 "OTKA" K-139184
6 · The paper itself

Abstract

Vascular graft maturation is associated with blood flow characteristics, such as velocity, pressure, vorticity, and wall shear stress (WSS). Many studies examined these factors separately. We aimed to examine the remodeling of arterio-venous fistulas (AVFs) and loop-shaped venous interposition grafts, together with 3D flow simulation. Thirty male Wistar rats were randomly and equally divided into sham-operated, AVF, and loop-shaped venous graft (Loop) groups, using the femoral and superficial inferior epigastric vessels for anastomoses. Five weeks after surgery, the vessels were removed for histological evaluation, or plastic castings were made and scanned for 3D flow simulation. Remodeling of AVF and looped grafts was complete in 5 weeks. Histology showed heterogeneous morphology depending on the distribution of intraluminal pressure and WSS. In the Loop group, an asymmetrical WSS distribution coincided with the intima hyperplasia spots. The tunica media was enlarged only when both pressure and WSS were high. The 3D flow simulation correlated with the histological findings, identifying "hotspots" for intimal hyperplasia formation, suggesting a predictive value. These observations can be useful for microvascular research and for quality control in microsurgical training.

Indexed as

3D flow simulationarterio-venous fistulaflow characteristicshistologyinterposition venous graftintimal hyperplasiavascular graftvascular regenerationwall shear stress

Identifiers

PMID35884813
PMCPMC9313372

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.