Evidence map›Paper›PMID 35884270›Full record

ArticleBiosensors2022

Detection of Oxytetracycline Using an Electrochemical Label-Free Aptamer-Based Biosensor.

Sanaz Akbarzadeh, Habibollah Khajehsharifi, Saeedeh Hajihosseini

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
3.2field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 42 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Review
  9. Article
  10. Article
  11. Review
  12. Review
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Sanaz AkbarzadehDepartment of Chemistry, Faculty of Science, Yasouj University, Yasouj 75918-74831, Iran.
Habibollah KhajehsharifiDepartment of Chemistry, Faculty of Science, Yasouj University, Yasouj 75918-74831, Iran.
Saeedeh HajihosseiniMedical Nanotechnology and Tissue Engineering Research Science Institute, Shahid Sadoughi University of Medical Science, Yazd 8919-5999, Iran.
Yasouj University · IRShahid Sadoughi University of Medical Sciences and Health Services · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

One of the most effective ways to detect and measure antibiotics is to detect their biomarkers. The best biomarker for the control and detection of oxytetracycline (OTC) is the OTC-specific aptamer. In this study, a novel, rapid, and label-free aptamer-based electrochemical biosensor (electrochemical aptasensor) was designed for OTC determination based on a newly synthesized nanocomposite including multi-walled carbon nanotubes (MWCNTs), gold nanoparticles (AuNPs), reduced graphene oxide (rGO), and chitosan (CS), as well as nanosheets to modify a glassy carbon electrode, which extremely enhanced electrical conductivity and increased the electrode surface to bind well with the amine-terminated OTC-specific aptamer through self-assembly. The (MWCNTs-AuNPs/CS-AuNPs/rGO-AuNPs) nanocomposite modified electrode was synthesized using a layer- by-layer modification method which had the highest efficiency for better aptamer stabilization. Differential pulse voltammetry (DPV), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM) techniques were used to investigate and evaluate the electrochemical properties and importance of the synthesized nanocomposite in different steps. The designed aptasensor was very sensitive for measuring the OTC content of milk samples, and the results were compared with those of our previously published paper. Based on the calibration curve, the detection limit was 30.0 pM, and the linear range was 1.00-540 nM for OTC. The repeatability and reproducibility of the aptasensor were obtained for 10.0 nM of OTC with a relative standard deviation (RSD%) of 2.39% and 4.01%, respectively, which were not affected by the coexistence of similar derivatives. The measurement in real samples with the recovery range of 93.5% to 98.76% shows that this aptasensor with a low detection limit and wide linear range can be a good tool for detecting OTC.

Indexed as

Aptamers, NucleotideBiosensing TechniquesGraphiteMetal NanoparticlesNanotubes, CarbonOxytetracyclineElectrochemical TechniquesElectrodesGoldLimit of DetectionReproducibility of ResultsAptamers, NucleotideGoldGraphiteNanotubes, CarbonOxytetracyclineaptasensordifferential pulse voltammetryelectrochemical impedance spectroscopynanocompositeoxytetracycline

Identifiers

PMID35884270
PMCPMC9313391
OpenAlexW4283693352

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.