Evidence map›Paper›PMID 35884254›Full record

ArticleBiosensors2022

New Microfluidic System for Electrochemical Impedance Spectroscopy Assessment of Cell Culture Performance: Design and Development of New Electrode Material.

Ayman Chmayssem, Constantin Edi Tanase, Nicolas Verplanck, Maxime Gougis, Véronique Mourier, Abdelkader Zebda, Amir M Ghaemmaghami, Pascal Mailley

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.1field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Review
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Ayman ChmayssemUniversity Grenoble Alpes, CEA, LETI, DTBS, F-38000 Grenoble, France.ORCID 0000-0002-2831-2626
Constantin Edi TanaseImmunology & Immuno-Bioengineering Group, School of Life Sciences, Faculty of Medicine & Health Sciences, University of Nottingham, Nottingham NG7 2RD, UK.
Nicolas VerplanckUniversity Grenoble Alpes, CEA, LETI, DTBS, F-38000 Grenoble, France.
Maxime GougisUniversity Grenoble Alpes, CEA, LETI, DTBS, F-38000 Grenoble, France.ORCID 0000-0003-1624-7203
Véronique MourierUniversity Grenoble Alpes, CEA, LETI, DTBS, F-38000 Grenoble, France.ORCID 0000-0002-6321-5012
Abdelkader ZebdaUniversity Grenoble Alpes, TIMC-IMAG/CNRS/INSERM, UMR 5525, F-38000 Grenoble, France.
Amir M GhaemmaghamiImmunology & Immuno-Bioengineering Group, School of Life Sciences, Faculty of Medicine & Health Sciences, University of Nottingham, Nottingham NG7 2RD, UK.ORCID 0000-0003-3160-8759
Pascal MailleyUniversity Grenoble Alpes, CEA, LETI, DTBS, F-38000 Grenoble, France.
Commissariat à l'Énergie Atomique et aux Énergies Alternatives · FRCentre National de la Recherche Scientifique · FRUniversity of Nottingham · GB

Funding

European Union 760921National Centre for the Replacement, Refinement and Reduction of Animals in Research NC/K500318/1
6 · The paper itself

Abstract

Electrochemical impedance spectroscopy (EIS) is widely accepted as an effective and non-destructive method to assess cell health during cell-culture. However, there is a lack of compact devices compatible with microfluidic integration and microscopy that could provide the real-time and non-invasive monitoring of cell-cultures using EIS. In this paper, we reported the design and characterization of a modular EIS testing system based on a patented technology. This device was fabricated using easily processable methodologies including screen-printing of the impedance electrodes and molding or micromachining of the cell culture chamber with an easy assembly procedure. Accordingly, to obtain processable, biocompatible and sterilizable electrode materials that lower the impact of interfacial impedance on TEER (Transepithelial electrical resistance) measurements, and to enable concomitant microscopy observations, we optimized the formulation of the electrode inks and the design of the EIS electrodes, respectively. First, electrode materials were based on carbon biocompatible inks enriched with IrOx particles to obtain low interfacial impedance electrodes approaching the performances of classical non-biocompatible Ag/AgCl second-species electrodes. Secondly, we proposed three original electrode designs, which were compared to classical disk electrodes that were optically compatible with microscopy. We assessed the impact of the electrode design on the response of the impedance sensor using COMSOL Multiphysics. Finally, the performance of the impedance spectroscopy devices was assessed in vitro using human airway epithelial cell cultures.

Indexed as

Dielectric SpectroscopyMicrofluidicsCell Culture TechniquesElectric ImpedanceElectrodesHumanscarbon-IrOx electrodescell-health monitoringelectrochemical impedance spectroscopymicrofluidic system

Identifiers

PMID35884254
PMCPMC9313146
OpenAlexW4283454573

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.