Evidence map›Paper›PMID 35883149›Full record

ArticleJournal of orthopaedic surgery and research2022

The optimal angle of screw for using cement-screw technique to repair tibial defect in total knee arthroplasty: a finite element analysis.

Guanghui Zhao, Shuxin Yao, Jianbing Ma, Jianpeng Wang

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Guanghui ZhaoDepartment of Joint Surgery, Honghui Hospital, Xi'An Jiaotong University, No. 555 East Youyi Road, Xi'an, Shanxi, China.
Shuxin YaoDepartment of Joint Surgery, Honghui Hospital, Xi'An Jiaotong University, No. 555 East Youyi Road, Xi'an, Shanxi, China.
Jianbing MaDepartment of Joint Surgery, Honghui Hospital, Xi'An Jiaotong University, No. 555 East Youyi Road, Xi'an, Shanxi, China.
Jianpeng WangDepartment of Joint Surgery, Honghui Hospital, Xi'An Jiaotong University, No. 555 East Youyi Road, Xi'an, Shanxi, China. 280771976@qq.com.
Xi'an Honghui Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe cement-screw technique is a convenient method to repair tibial plateau defects in primary and revision total knee arthroplasty (TKA). However, the optimal angle of screw insertions is unknown. This study aimed to perform a finite element analysis (FEA) to determine the optimal screw angle for the repair of tibial plateau defects in TKA.

methodsSeven FEA models were set and two common different defects (defect 1: area < 12%, depth < 12 mm; defect 2: area > 12%, depth > 12 mm) were simulated. One screw was used in defect 1, and one or two screws were used in defect 2. Screws were parallel to the proximal cortical bone (oblique screw) or perpendicular to the upper surface (vertical screw) of the tibia. Contact stresses on cancellous bone in different areas were determined. Maximum principal stress on the cancellous bone around each screw was also compared.

resultsThe FEA models showed that stresses on the surface of cancellous bone in tibial defect (0.13-0.39 MPa) and stress focus spot (0.45 MPa) around the screw were lower when one vertical screw was used in defect 1. The stresses on the surface of cancellous bone in tibial defect (0.09-0.44 MPa), stresses in the medial tibial plateau (0.14-0.21 MPa), and stress focus spot around the screws were lowest (0.42 MPa and 1.37 MPa) when two vertical screws were used in defect 2, followed by of one vertical and one oblique (0.16-0.48 MPa; 0.15-0.21 MPa; 1.63 MPa and 1.11 MPa). No other statistically significant differences were found.

conclusionsEither for one or two screws, those perpendicular to the upper surface achieve better stability than those parallel to the proximal cortical bone of the tibia. If two vertical screws cannot be performed, one vertical and one oblique is also acceptable.

Indexed as

Arthroplasty, Replacement, KneeTibiaBiomechanical PhenomenaBone CementsBone ScrewsFinite Element AnalysisKnee JointBone CementsBone defectCement-screw techniqueFinite element analysisTotal knee arthroplasty

Identifiers

PMID35883149
PMCPMC9327380
OpenAlexW4288009938

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.