ArticleBioelectronic medicine2022
Effects of waveform shape and electrode material on KiloHertz frequency alternating current block of mammalian peripheral nerve.
Article in Bioelectronic medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 10 citations in OpenAlex.
- Optimization of electrode material and geometry to enhance TTFields-like anticancer effects in MCF-7 breast cancer cells.Scientific reports · 2026Article
- Single-Electrode, Bidirectional Control of Heart Rate via Vagus Nerve Modulation in Rat Model.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026Article
- Electrophysiological Methods to Assess Peripheral Pain Block in an Anesthetized Rat.Journal of visualized experiments : JoVE · 2025Article
- Ramped kilohertz-frequency signals produce nerve conduction block without onset response.Journal of neural engineering · 2025Article
- Neurocardiology: translational advancements and potential.The Journal of physiology · 2025Review
- Temporal properties of transcutaneous direct current motor conduction block.Journal of neural engineering · 2025Article
- Closed-Loop Multimodal Neuromodulation of Vagus Nerve for Control of Heart Rate.Proceedings of the ... American Control Conference. American Control Conference · 2024Article
- Bioelectronic modulation of carotid sinus nerve to treat type 2 diabetes: current knowledge and future perspectives.Frontiers in neuroscience · 2024Review
- Stimulation parameters for directional vagus nerve stimulation.Bioelectronic medicine · 2023Article
- Spatiotemporal parameters for energy efficient kilohertz-frequency nerve block with low onset response.Journal of neuroengineering and rehabilitation · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
Abstract
objectivesKiloHertz frequency alternating current waveforms produce conduction block in peripheral nerves. It is not clearly known how the waveform shape affects block outcomes, and if waveform effects are frequency dependent. We determined the effects of waveform shape using two types of electrodes. MATERIALS AND
methodsAcute in-vivo experiments were performed on 12 rats. Bipolar electrodes were used to electrically block motor nerve impulses in the sciatic nerve, as measured using force output from the gastrocnemius muscle. Three blocking waveforms were delivered (sinusoidal, square and triangular) at 6 frequencies (10-60 kHz). Bare platinum electrodes were compared with carbon black coated electrodes. We determined the minimum amplitude that could completely block motor nerve conduction (block threshold), and measured properties of the onset response, which is a transient period of nerve activation at the start of block. In-vivo results were compared with computational modeling conducted using the NEURON simulation environment using a nerve membrane model modified for stimulation in the kilohertz frequency range.
resultsFor the majority of parameters, in-vivo testing and simulations showed similar results: Block thresholds increased linearly with frequency for all three waveforms. Block thresholds were significantly different between waveforms; lowest for the square waveform and highest for triangular waveform. When converted to charge per cycle, square waveforms required the maximum charge per phase, and triangular waveforms the least. Onset parameters were affected by blocking frequency but not by waveform shape. Electrode comparisons were performed only in-vivo. Electrodes with carbon black coatings gave significantly lower block thresholds and reduced onset responses across all blocking frequencies. For 10 and 20 kHz, carbon black coating significantly reduced the charge required for nerve block.
conclusionsWe conclude that both sinusoidal and square waveforms at frequencies of 20 kHz or higher would be optimal. Future investigation of carbon black or other high charge capacity electrodes may be useful in achieving block with lower BTs and onsets. These findings will be of importance for designing clinical nerve block systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.