Evidence map›Paper›PMID 35882533›Full record

ArticleEuropean journal of hospital pharmacy : science and practice2024

Factors influencing accuracy when preparing injectable drug concentrations in appliance with clinical practice: a norepinephrine case study.

Sixtine Gilliot, Anthony Martin Mena, Stéphanie Genay, Morgane Masse, Manon Thibaut, Natacha Carta, Damien Lannoy, Laura Négrier, Christine Barthélémy, Bertrand Décaudin and 1 more

Abstract read
In one paragraph

Article in European journal of hospital pharmacy : science and practice, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Sixtine GilliotInstitute of Pharmacy, CHRU Lille Pôle Spécialités Médicochirurgicales, Lille, Hauts-de-France, France sixtine.gilliot@univ-lille.fr.ORCID 0000-0001-7944-7443
Anthony Martin MenaULR-7365 Groupe de Recherche sur les formes Injectables et les Technologies Associées, University of Lille, Lille, Hauts-de-France, France.
Stéphanie GenayInstitute of Pharmacy, CHRU Lille Pôle Spécialités Médicochirurgicales, Lille, Hauts-de-France, France.
Morgane MasseInstitute of Pharmacy, CHRU Lille Pôle Spécialités Médicochirurgicales, Lille, Hauts-de-France, France.
Manon ThibautULR-7365 Groupe de Recherche sur les formes Injectables et les Technologies Associées, University of Lille, Lille, Hauts-de-France, France.
Natacha CartaULR-7365 Groupe de Recherche sur les formes Injectables et les Technologies Associées, University of Lille, Lille, Hauts-de-France, France.
Damien LannoyInstitute of Pharmacy, CHRU Lille Pôle Spécialités Médicochirurgicales, Lille, Hauts-de-France, France.
Laura NégrierULR-7365 Groupe de Recherche sur les formes Injectables et les Technologies Associées, University of Lille, Lille, Hauts-de-France, France.
Christine BarthélémyULR-7365 Groupe de Recherche sur les formes Injectables et les Technologies Associées, University of Lille, Lille, Hauts-de-France, France.
Bertrand DécaudinInstitute of Pharmacy, CHRU Lille Pôle Spécialités Médicochirurgicales, Lille, Hauts-de-France, France.
Pascal OdouInstitute of Pharmacy, CHRU Lille Pôle Spécialités Médicochirurgicales, Lille, Hauts-de-France, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Errors in injectable preparations with high-risk drugs can be fatal. This study aimed to identify the factors influencing the accuracy of high-risk injectable drug concentrations in appliances used for intensive care unit preparation practices. Norepinephrine (NE) was chosen as an example of a high-risk medication drug. The concentration (0.2 and 0.5 mg/mL), the diluent (sodium chloride 0.9% and 5% dextrose), and the container type (prefilled- and empty-infusion bag and syringe) were tested as potential variability factors. An ultraviolet spectrophotometric method was used for NE dosage. 108 NE solutions were prepared by five individuals (pharmacists or laboratory technicians) with clinical experience as well as experience in the aseptic preparation of solutions. The container type was found to be the only factor influencing the accuracy of NE concentration. NE solutions in syringes proved to be the most accurate while preparations in prefilled bags tended to underdose NE.

Indexed as

NorepinephrineSyringesHumansInfusions, ParenteralNorepinephrineAdministration, IntravenousCritical CareDrug CompoundingMEDICAL ERRORSPHARMACEUTICAL PREPARATIONS

Identifiers

PMID35882533
PMCPMC10895172

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.