Evidence map›Paper›PMID 35877354›Full record

ArticleBioengineering (Basel, Switzerland)2022

Actuator and Contact Force Modeling of an Active Soft Brace for Scoliosis.

Athar Ali, Vigilio Fontanari, Werner Schmoelz, Marco Fontana

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Athar AliDepartment of Industrial Engineering, University of Trento, 38123 Trento, Italy.ORCID 0000-0002-5936-447X
Vigilio FontanariDepartment of Industrial Engineering, University of Trento, 38123 Trento, Italy.ORCID 0000-0001-8236-522X
Werner SchmoelzDepartment of Orthopedics and Traumatology, Medical University of Innsbruck, 6020 Innsbruck, Austria.ORCID 0000-0003-2962-2594
Marco FontanaInstitute of Mechanical Intelligence, Scuola Superiore Sant'Anna, 56010 Pisa, Italy.
University of Trento · ITInnsbruck Medical University · ATScuola Superiore Sant'Anna · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Scoliosis is an abnormality of the spinal curvature that severely affects the musculoskeletal, respiratory, and nervous systems. Conventionally, it is treated using rigid spinal braces. These braces are static, rigid, and passive in nature, and they (largely) limit the mobility of the spine, resulting in other spinal complexities. Moreover, these braces do not have precise control over how much force is being applied by them. Over-exertion of force may deteriorate the spinal condition. This article presents a novel active soft brace that allows mobility to the spine while applying controlled corrective forces that are regulated by varying the tensions in elastic bands using low-power light weight twisted string actuators (TSAs). This article focuses on the actuator and contact force modeling of the active soft brace (ASB). The actuator modeling is required to translate the twisting of string in terms of contraction of the string's length, whereas the contact force modeling helps in estimating the net resultant force exerted by the band on the body using single point pressure/force sensors. The actuators (TSAs) are modeled as helix geometry and validated using a laser position sensor. The results showed that the model effectively tracked the position (contraction in length) with root mean square error (RMSE) of 1.7386 mm. The contact force is modeled using the belt and pulley contact model and validated by building a custom testbed. The actuator module is able to regulate the pressure in the range 0-6 Kpa, which is comparable to 0-8 Kpa pressure regulated in rigid braces. This makes it possible to verify and demonstrate the working principle of the proposed active soft brace.

Indexed as

exoskeletonsmodelingscoliosissoft bracetwisted string actuators (TSA)wearable robotics

Identifiers

PMID35877354
PMCPMC9311770
OpenAlexW4285010384

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.