Automatic Identification of Failure in Hip Replacement: An Artificial Intelligence Approach.

Mattia Loppini, Francesco Manlio Gambaro, Katia Chiappetta, Guido Grappiolo, Anna Maria Bianchi, Valentina D A Corino

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mattia LoppiniDepartment of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, MI, Italy.ORCID 0000-0001-8569-0669
Francesco Manlio GambaroDepartment of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, MI, Italy.
Katia ChiappettaIRCCS Humanitas Research Hospital, Via Alessandro Manzoni 56, 20089 Rozzano, MI, Italy.
Guido GrappioloIRCCS Humanitas Research Hospital, Via Alessandro Manzoni 56, 20089 Rozzano, MI, Italy.
Anna Maria BianchiDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20131 Milan, MI, Italy.ORCID 0000-0002-8290-7460
Valentina D A CorinoDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20131 Milan, MI, Italy.ORCID 0000-0003-1825-0422

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Total hip arthroplasty (THA) follow-up is conventionally conducted with serial X-ray imaging in order to ensure the early identification of implant failure. The purpose of this study is to develop an automated radiographic failure detection system. Methods: 630 patients with THA were included in the study, two thirds of which needed total or partial revision for prosthetic loosening. The analysis is based on one antero-posterior and one lateral radiographic view obtained from each patient during routine post-surgery follow-up. After pre-processing for proper standardization, images were analyzed through a convolutional neural network (the DenseNet169 network), aiming to predict prosthesis failure. The entire dataset was divided in three subsets: training, validation, and test. These contained transfer learning and fine-tuning algorithms, based on the training dataset, and were implemented to adapt the DenseNet169 network to the specific data and clinical problem. Results: After the training procedures, in the test set, the classification accuracy was 0.97, the sensitivity 0.97, the specificity 0.97, and the ROC AUC was 0.99. Only five images were incorrectly classified. Seventy-four images were classified as failed, and eighty as non-failed with a probability >0.999. Conclusion: The proposed deep learning procedure can detect the loosening of the hip prosthesis with a very high degree of precision.

Indexed as

bioengineeringhip prothesismachine learningorthopedics

Identifiers

PMID35877339
PMCPMC9312125

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.