ArticleCureus2022
Inappropriate Subcutaneous Implantable Cardioverter Defibrillator Shocks Secondary to Cardiac Remodeling: A Unique Case of T Wave Oversensing.
Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 2 citations in OpenAlex.
- "Once Shocked, Twice Shy": A case of post-traumatic stress disorder after a single inappropriate ICD shock.HeartRhythm case reports · 2026Article
- Intra-Abdominal Hemorrhage Triggering Inappropriate Therapy From a Subcutaneous Defibrillator.JACC. Case reports · 2024Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Implantable cardioverter defibrillators (ICD) are used for the primary and secondary prevention of sudden cardiac death (SCD). Currently, two different modalities of ICDs are in use: transvenous (TV) and subcutaneous (S-ICD). The use of S-ICDs has been driven by several potential benefits of this technology: preservation of central venous vasculature, no risk of vascular or myocardial injury during implant, easier explanation, and lower risk of systemic infections. Inappropriate shocks are defined as shocks delivered for non-life-threatening arrhythmias or because of oversensing. Here, we present a case of a 58-year-old man who began experiencing inappropriate shocks three years after S-ICD placement. Careful analysis of the ICD showed T wave oversensing with no malfunction of the device. The shocks persisted even after reprogramming, leading to subsequent ICD removal and loop recorder implantation. The onset of shock episodes coincided with the improvement of left ventricular ejection fraction (LVEF). To the best of our knowledge, this is the first published report of cardiac remodeling leading to uncorrectable T wave oversensing that subsequently required S-ICD explant. This represents a potentially important limitation of S-ICD technology, especially as S-ICD use rises and medical therapy for cardiomyopathy continues to improve.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.