Evidence map›Paper›PMID 35873899›Full record

ArticleIEEE access : practical innovations, open solutions2022

Vivaldi Antennas for Contactless Sensing of Implant Deflections and Stiffness for Orthopaedic Applications.

Jakob G Wolynski, Milan M Ilić, Branislav M Notaroš, Kevin M Labus, Christian M Puttlitz, Kirk C McGilvray

Abstract read
In one paragraph

Article in IEEE access : practical innovations, open solutions, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Observational
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jakob G WolynskiDepartment of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA.ORCID 0000-0003-2659-337X
Milan M IlićSchool of Electrical Engineering, University of Belgrade, 11120 Belgrade, Serbia.ORCID 0000-0003-4196-3594
Branislav M NotarošDepartment of Electrical and Computer Engineering, Colorado State University, Fort Collins, CO 80523, USA.ORCID 0000-0002-5755-961X
Kevin M LabusDepartment of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA.
Christian M PuttlitzDepartment of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA.
Kirk C McGilvrayDepartment of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA.ORCID 0000-0003-1302-9307

Funding

Early Detecton and Prediction of Complex Bone Fracture HealingR01AR069734 · NIAMS · COLORADO STATE UNIVERSITY · PI MCGILVRAY, KIRK · 2016 to 2020
$2.6M
NIAMS NIH HHS R01 AR069734
6 · The paper itself

Abstract

The implementation of novel coaxial dipole antennas has been shown to be a satisfactory diagnostic platform for the prediction of orthopaedic bone fracture healing outcomes. These techniques require mechanical deflection of implanted metallic hardware (i.e., rods and plates), which, when loaded, produce measurable changes in the resonant frequency of the adjacent antenna. Despite promising initial results, the coiled coaxial antenna design is limited by large antenna sizes and nonlinearity in the resonant frequency data. The purpose of this study was to develop two Vivaldi antennas (a.k.a., "standard" and "miniaturized") to address these challenges. Antenna behaviors were first computationally modeled prior to prototype fabrication. In subsequent benchtop tests, metallic plate segments were displaced from the prototype antennas via precision linear actuator while measuring resultant change in resonant frequency. Close agreement was observed between computational and benchtop results, where antennas were highly sensitive to small displacements of the metallic hardware, with sensitivity decreasing nonlinearly with increasing distance. Greater sensitivity was observed for the miniaturized design for both stainless steel and titanium implants. Additionally, these data demonstrated that by taking resonant frequency data during implant displacement and then again during antenna displacement from the same sample, via linear actuators, that "antenna calibration procedures" could be used to enable a clinically relevant quantification of fracture stiffness from the raw resonant frequency data. These improvements mitigate diagnostic challenges associated with nonlinear resonant frequency response seen in previous antenna designs.

Indexed as

Antenna for orthopaedic applicationantenna resonant frequencycomputational electromagnetic simulationselectromagnetic sensorexternal sensing of object displacement/deflection/stiffnessmonitoring and predicting bone fracture healingnear electromagnetic fieldresonant frequency measurementsVivaldi antenna

Identifiers

PMID35873899
PMCPMC9307137

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.