Evidence map›Paper›PMID 35871703›Full record

ArticleAnalytical and bioanalytical chemistry2022

Development of a scoring parameter to characterize data quality of centroids in high-resolution mass spectra.

Max Reuschenbach, Lotta L Hohrenk-Danzouma, Torsten C Schmidt, Gerrit Renner

Abstract read
In one paragraph

Article in Analytical and bioanalytical chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Max ReuschenbachInstrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany.
Lotta L Hohrenk-DanzoumaInstrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany.
Torsten C SchmidtInstrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany.
Gerrit RennerInstrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany. gerrit.renner@uni-due.de.ORCID http://orcid.org/0000-0003-3808-5890

Funding

Friedrich-Ebert-Stiftung PhD scholarship
6 · The paper itself

Abstract

High-resolution mass spectrometry is widely used in many research fields allowing for accurate mass determinations. In this context, it is pretty standard that high-resolution profile mode mass spectra are reduced to centroided data, which many data processing routines rely on for further evaluation. Yet information on the peak profile quality is not conserved in those approaches; i.e., describing results reliability is almost impossible. Therefore, we overcome this limitation by developing a new statistical parameter called data quality score (DQS). For the DQS calculations, we performed a very fast and robust regression analysis of the individual high-resolution peak profiles and considered error propagation to estimate the uncertainties of the regression coefficients. We successfully validated the new algorithm with the vendor-specific algorithm implemented in Proteowizard's msConvert. Moreover, we show that the DQS is a sum parameter associated with centroid accuracy and precision. We also demonstrate the benefit of the new algorithm in nontarget screenings as the DQS prioritizes signals that are not influenced by non-resolved isobaric ions or isotopic fine structures. The algorithm is implemented in Python, R, and Julia programming languages and supports multi- and cross-platform downstream data handling.

Indexed as

AlgorithmsData AccuracyIonsMass SpectrometryReproducibility of ResultsIonsCentroidingData processingData qualityHRMS

Identifiers

PMID35871703
PMCPMC9411079

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.