Evidence map›Paper›PMID 35865397›Full record

ArticleMediterranean journal of hematology and infectious diseases2022

Back to the "Gold Standard": How Precise is Hematocrit Detection Today?

Leonid Livshits, Tal Bilu, Sari Peretz, Anna Bogdanova, Max Gassmann, Harel Eitam, Ariel Koren, Carina Levin

Open access · goldAbstract read
In one paragraph

Article in Mediterranean journal of hematology and infectious diseases, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Leonid LivshitsRed Blood Cell Research Group, Vetsuisse Faculty, Institute of Veterinary Physiology, University of Zurich, Zürich, Switzerland.
Tal BiluPediatric Hematology Unit, Emek Medical Center, Afula, Israel.
Sari PeretzPediatric Hematology Unit, Emek Medical Center, Afula, Israel.
Anna BogdanovaRed Blood Cell Research Group, Vetsuisse Faculty, Institute of Veterinary Physiology, University of Zurich, Zürich, Switzerland.
Max GassmannRed Blood Cell Research Group, Vetsuisse Faculty, Institute of Veterinary Physiology, University of Zurich, Zürich, Switzerland.
Harel EitamLaboratory Division Unit, Emek Medical Center, Afula, Israel.
Ariel KorenPediatric Hematology Unit, Emek Medical Center, Afula, Israel.
Carina LevinPediatric Hematology Unit, Emek Medical Center, Afula, Israel.
Emek Medical Center · ILUniversity of Zurich · CHTechnion – Israel Institute of Technology · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The commonly used method for hematocrit detection, by visual examination of microcapillary tube, known as "micro-HCT", is subjective but remains one of the key sources for fast hematocrit evaluation. Analytical automation techniques have increased the standardization of RBC index detection; however, indirect hematocrit measurements by blood analyzer, the automated HCT, do not correlate well with "micro-HCT" results in patients with hematological pathologies. We aimed to overcome those disadvantages in "micro-HCT" analysis using "ImageJ" processing software. Methods: 223 blood samples from the "general population" and 19 from sickle cell disease patients were examined in parallel for hematocrit values using the automated HCT, standard "micro-HCT," and "ImageJ" micro-HCT methods. Results: For the "general population" samples, the "ImageJ" values were significantly higher than the corresponding values evaluated by standard "micro-HCT" and automated HCT, except for the 0 to 2 month old newborns, in which the automated HCT results were similar to the "ImageJ" evaluated HCT. Similar to the "general population" cohort, we found significantly higher values measured by "ImageJ" compared to either "micro-HCT" or the automated HCT in SCD patients. Correspondent differences for the MCV and MCHC were also found. Discussion: This study introduces the "micro-HCT" assessment technique using the image-analysis module of "ImageJ" software. This procedure allows overcoming most of the data errors associated with the standard "micro-HCT" evaluation and can replace the use of complicated and expensive automated equipment. The presented results may also be used to develop new standards for calculating hematocrit and associated parameters for routine clinical practice.

Indexed as

Image analysisMicrocapillary hematocritRBC indices

Identifiers

PMID35865397
PMCPMC9266461
OpenAlexW4286768800

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.