Evidence map›Paper›PMID 35865006›Full record

ArticleFrontiers in molecular biosciences2022

FSCC: Few-Shot Learning for Macromolecule Classification Based on Contrastive Learning and Distribution Calibration in Cryo-Electron Tomography.

Shan Gao, Xiangrui Zeng, Min Xu, Fa Zhang

Abstract read
In one paragraph

Article in Frontiers in molecular biosciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Shan GaoHigh Performance Computer Research Center, Institute of Computing Technology, Chinese Academy of Sciences, Beijing, China.
Xiangrui ZengComputational Biology Department, School of Computer Science, Carnegie Mellon University, Pittsburgh, PA, United States.
Min XuComputational Biology Department, School of Computer Science, Carnegie Mellon University, Pittsburgh, PA, United States.
Fa ZhangHigh Performance Computer Research Center, Institute of Computing Technology, Chinese Academy of Sciences, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cryo-electron tomography (Cryo-ET) is an emerging technology for three-dimensional (3D) visualization of macromolecular structures in the near-native state. To recover structures of macromolecules, millions of diverse macromolecules captured in tomograms should be accurately classified into structurally homogeneous subsets. Although existing supervised deep learning-based methods have improved classification accuracy, such trained models have limited ability to classify novel macromolecules that are unseen in the training stage. To adapt the trained model to the macromolecule classification of a novel class, massive labeled macromolecules of the novel class are needed. However, data labeling is very time-consuming and labor-intensive. In this work, we propose a novel few-shot learning method for the classification of novel macromolecules (named FSCC). A two-stage training strategy is designed in FSCC to enhance the generalization ability of the model to novel macromolecules. First, FSCC uses contrastive learning to pre-train the model on a sufficient number of labeled macromolecules. Second, FSCC uses distribution calibration to re-train the classifier, enabling the model to classify macromolecules of novel classes (unseen class in the pre-training). Distribution calibration transfers learned knowledge in the pre-training stage to novel macromolecules with limited labeled macromolecules of novel class. Experiments were performed on both synthetic and real datasets. On the synthetic datasets, compared with the state-of-the-art (SOTA) method based on supervised deep learning, FSCC achieves competitive performance. To achieve such performance, FSCC only needs five labeled macromolecules per novel class. However, the SOTA method needs 1100 ∼ 1500 labeled macromolecules per novel class. On the real datasets, FSCC improves the accuracy by 5% ∼ 16% when compared to the baseline model. These demonstrate good generalization ability of contrastive learning and calibration distribution to classify novel macromolecules with very few labeled macromolecules.

Indexed as

contrastive learningcryo-ETdistribution calibrationfew-shot learningmacromolecule classification

Identifiers

PMID35865006
PMCPMC9294403

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.