Evidence map›Paper›PMID 35862982›Full record

ArticleMicrobiology spectrum2022

Performance of 22 Rapid Lateral Flow Tests for SARS-CoV-2 Antigen Detection and Influence of "Variants of Concern": Implications for Clinical Use.

Aurélie Gourgeon, Alexandre Soulier, Étienne Audureau, Souraya Khouider, Arnaud Galbin, Camille Langlois, Magali Bouvier-Alias, Christophe Rodriguez, Stéphane Chevaliez, Jean-Michel Pawlotsky and 1 more

Abstract read
In one paragraph

Article in Microbiology spectrum, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Aurélie Gourgeon *Department of Virology, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, Université Paris-Est, Créteil, France.
Alexandre Soulier *Department of Virology, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, Université Paris-Est, Créteil, France.
Étienne Audureau *INSERM U955, Institut Mondor de Recherche Biomédicale, Créteil, France.
Souraya KhouiderDepartment of Virology, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, Université Paris-Est, Créteil, France.
Arnaud GalbinDepartment of Virology, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, Université Paris-Est, Créteil, France.
Camille LangloisDepartment of Virology, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, Université Paris-Est, Créteil, France.
Magali Bouvier-AliasDepartment of Virology, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, Université Paris-Est, Créteil, France.
Christophe RodriguezDepartment of Virology, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, Université Paris-Est, Créteil, France.
Stéphane ChevaliezDepartment of Virology, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, Université Paris-Est, Créteil, France.ORCID 0000-0001-6913-9017
Jean-Michel Pawlotsky *Department of Virology, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, Université Paris-Est, Créteil, France.ORCID 0000-0003-0745-7559
Slim Fourati *Department of Virology, Henri Mondor Hospital, Assistance Publique-Hôpitaux de Paris, Université Paris-Est, Créteil, France.ORCID 0000-0002-1236-5467

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Large-scale head-to-head assessment of the performance of lateral-flow tests (LFTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen is required in the context of the continuous emergence of new viral variants. The aim of this study was to evaluate the performance of 22 rapid LFTs for the detection of SARS-CoV-2 antigens. The clinical performance of 22 LFTs was evaluated in 1,157 samples collected in the Greater Paris area. The 8 best-performing LFTs were further assessed for their ability to detect 4 variants of concern (VOC), including the alpha, beta, delta, and omicron (BA.1) variants. The specificity of SARS-CoV-2 LFTs was generally high (100% for 15 of them) but was insufficient (<75%) for 3 tests. Sensitivity of the LFTs varied from 30.0% to 79.7% compared to nucleic acid amplification testing (NAAT). Using a cycle threshold (

Indexed as

COVID-19Nucleic AcidsHumansSARS-CoV-2Serologic TestsNucleic Acidslateral-flow testsSARS CoV-2variants of concern

Identifiers

PMID35862982
PMCPMC9430704

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.