Evidence map›Paper›PMID 35861922›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2023

The accuracy of hip fracture data entered into the national surgical quality improvement program (NSQIP) database.

Violette C Simon, Nicholas J Tucker, Alla Balabanova, Joshua A Parry

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Declining mortality after open pelvis fracture in North America.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025
    Article
  3. Article
  4. NSQIP data collection up to 30 postoperative days is sufficient to capture some complications in orthopedic surgeries.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Violette C SimonUniversity of Colorado School of Medicine, Aurora, CO, USA.
Nicholas J TuckerUniversity of Colorado School of Medicine, Aurora, CO, USA.
Alla BalabanovaUniversity of Colorado School of Medicine, Aurora, CO, USA.
Joshua A ParryUniversity of Colorado School of Medicine, Aurora, CO, USA. Joshua.alan.parry@gmail.com.ORCID http://orcid.org/0000-0002-8262-4065

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeInternal validation studies of National Surgical Quality Improvement Program (NSQIP) registry data have reported potential inaccuracies. The purpose of this study was to determine the accuracy of hip fracture CPT codes and complications entered into NSQIP for a single participating center.

methodsA retrospective study identified patients with a hip fracture CPT code from NSQIP data at a single institution over a two-year period. CPT codes included 27235 (percutaneous fixation of femoral neck fracture (Perc FNFX)), 27236 (open treatment of femoral neck fracture, internal fixation/prosthetic replacement (Open FNFX)), 27244 (open treatment of inter/peri/subtrochanteric femoral fracture with plate (Plate ITFX)), 27245 (treatment of inter/peri/subtrochanteric femoral fracture, with intramedullary implant (IMN ITFX)), and 27125 (hemiarthroplasty (HA)). The institutional medical record was reviewed to determine the accuracy of CPT code and 30-day complication data entered into the registry.

result12.8% (n = 20/156) of patients had an inaccurate CPT code. The proportion of inaccurate CPT codes varied significantly by procedure: Plate ITFX (76.9%), Open FNFX (13.8%), IMN ITFX (7.0%), and HA (0%) (p < 0.0001). A total of 82 complications were identified in 66 patients via the medical record. 43.9% (n = 36/82) of these complications were not documented in the NSQIP data. The proportion of missing complications varied significantly by type: renal (100%), UTI (53.8%), infection (50%), bleeding (30%), death (25%), respiratory (25%), cardiac (0%), stroke (0%), and VTE (0%) (p < 0.0001).

conclusionHip fracture CPT codes and 30-day complication data entered into the NSQIP registry were frequently inaccurate. Studies incorporating NSQIP data should acknowledge these potential limitations of the registry, and future research to validate NSQIP orthopedic data across procedures and institutions is necessary. LEVEL OF EVIDENCE: LEVEL III: Diagnostic study.

Indexed as

Femoral Neck FracturesHip FracturesHumansPostoperative ComplicationsQuality ImprovementRetrospective Studies30-day complicationsCPT codeHip fractureNSQIPRegistry data

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.